00191663.pdf - 第17页
Retrofit Instructions 80F5 DCA Option 05/99 issue 1 Overview 17 1O v e r v i e w These ins tructio ns describe how to retr ofit the DC A option f or SIPLA CE 80F5 placemen t sys- tems. 1 T o retrofit th e DCA op tion, th…
DCA-Option Nachrüstanleitung 80F5
Ausgabe 05/99
16

Retrofit Instructions 80F5 DCA Option
05/99 issue 1 Overview
17
1Overview
These instructions describe how to retrofit the DCA option for SIPLACE 80F5 placement sys-
tems. 1
To retrofit the DCA option, the 6-nozzle revolver head of the 80F5 placement system must be
equipped with a new component camera system. The vision analysis unit in the control unit is also
replaced with a unit that also incorporates the DCA option. 1
The DCA component camera system essentially consists of the following components: 1
– New camera housing (item 1 in Fig. 1 - 1)
– New CCD camera with 4 illumination planes
– New illumination board for the illumination control (item 2 in Fig. 1 - 1)
– New ribbon cable for the star motor (item 4 in Fig. 1 - 1)
– New cover for the 6-nozzle revolver head with FC camera
– MVS 340 vision analysis unit, DCA option (item 1 in Fig. 1 - 2)
This will enable the 6-nozzle revolver head to insert 1
– flip-chips and
– bare dies
on the 80F5 placement system, in addition to standard components. 1
PLEASE NOTE: 1
The camera system and illumination control form a single unit and must always be replaced to-
gether during servicing. 1

DCA Option Retrofit Instructions 80F5
05/99 issue
18
1
Fig. 1 - 1 DCA camera system
Key to Fig. 1 - 1
(1) FC camera 16 x 16
(2) Illumination control board
(3) 6-nozzle revolver head
(4) Ribbon cable for the star motor
1
2
3
4