00198108-01_JC_PM_WF3_TX_EN.pdf - 第55页
18 WF 3 TX-Series Maintenance Calibrating CPP Head 14 min 1 / 4 C A U T I O N ! R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n a n c e Machine St…

www.asm-smt.com

18 WF 3 TX-Series Maintenance Calibrating CPP Head 14 min 1 / 4
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T2, T5
Wear Part: Consumables:
www.asm-smt.com
1 Press the stop button. 2 Open the cover. 3 Place the calibration tool in pocket.
4 Close cover. 5 Do not click machine start button. 6 Click on "settings and options" (1) icon.

18 WF 3 TX-Series Maintenance Calibrating CPP Head 14 min 2 / 4
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T2, T5
Wear Part: Consumables:
www.asm-smt.com
7 Click on "user settings" (1) icon. 8 Click on "machine service" icon. 9 Click on "calibration" icon.
10 Click on "fast hardware exchange" icon 11 Select "head exchange" icon. 12 Select the head to be calibrated.