TDS-injet-388-CRD_31.10..pdf - 第6页
InJet ® 388 CRD TECHNICAL DATA SHEET www.dct.cleaning 6 1 process chamber, full automatic solution 100% closed loop uid system 2 arm rotation - uid powered - cleaning 2 arm rotation - uid powered - rinsing Cleaning an…

InJet
®
388 CRD
TECHNICAL DATA SHEET
www.dct.cleaning
5
metric units imperial units
Power supply 400 V, 32A, 50Hz (3+N+PE) UL 400 V, 32A, 60Hz (3+N+PE)
Pmax 12 kW 12 kW
Connection to central air pressure Pipe Ø 6 mm Pipe ID 0.24 in
Recommended working pressure 5 Bar 72.5 PSI
Exhaust pipe diameter Ø 100 mm ID 3.94 in
Exhaust pipe capacity 380 m
3
/h 13400 ft
3
/h
Minimum liquid for rst ll 2 x 50 L 2 x 13,2 gal
Service space required around the device 600 mm 23.6 in
INSTALLATION REQUIREMENTS
BACK
VIEW
discharge of uids G1“
225 mm / 8.86 in
Ø 100 mm
ID 3.94 in
input air pressure 1x Ø6 mm
input air pressure 1 x ID 0.24 in
400 V, 32A, 50Hz (3+N+PE)
UL 400 V, 32A, 60Hz (3+N+PE)
490 mm
19.3 in

InJet
®
388 CRD
TECHNICAL DATA SHEET
www.dct.cleaning
6
1 process chamber, full automatic solution
100% closed loop uid system
2 arm rotation - uid powered - cleaning
2 arm rotation - uid powered - rinsing
Cleaning and rinsing uid heating
High-capacity mechanical ltration on all cycles
Hot air drying
Chimney ap - electronically controlled
Pneumatic door lock
Emergency stop button
Manipulation wheels - lockable
Electronic monitoring of the uid pressure
PLC controller + 8,4“ touchscreen
Spare parts (base kit)
STANDARD HARDWARE EQUIPMENT
Electronic monitoring of uid level
Electronic monitoring of uid pressure
Electronic cycle counter
3 level of logging - operator, maintenance, technician
1 process chamber - fully automatic solution
Spraying uid pressure - continuous measurement
Standard software language mutation - CZ, ENG
Liquid and lter replacement notication – cycle counting
Possibility of 5 programs - setting option
Smart warning - low or high pressure level
Smart warning - low uid level
STANDARD SOFTWARE EQUIPMENT

InJet
®
388 CRD
TECHNICAL DATA SHEET
www.dct.cleaning
7
SW for CVA calculation ( android, machine )
Adjustable timer of cleaning uid heating
Upgrade machine for PROTON 69
Language mutation (CZE, ENG, GER, POL, CHI, RUS, ITA, SPA, MAY, HUN)
Online access to cleaning device
and other equipment ...
OPTIONAL SOFTWARE EQUIPMENT
Joint liquid discharge - manual control
Automatic liquid rell
Automatic liquid discharge
Tanker 200 and 400 litres for operational liguid
1PR sandwich ltration - integrated
2PR sandwich ltration - integrated
Sandwich ltration - external
and other equipment ...
OPTIONAL HARDWARE EQUIPMENT
Mechanical table holder - stencil or PCB carrier frame
Mechanical carrier frame - PCB
Mechanical carrier frame - frameless stencils
Mechanical carrier frame - VectorGuard stencils
Mechanical carrier frame - squeegees
and other equipment ...
Traceability OFF line, CSV to SD card
Traceability OFF line, Reader, CSV to SD card
Traceability ON line, PC WIN, le
Traceability ON line, READER, PC WIN, le
Traceability ON line, PC WIN, OPC Server CD, no le
Traceability ON line, PC WIN, READER, OPC Server CD, no le
and other options ...
OPTIONAL ACCESSORY – FRAMES AND OTHERS
OPTIONAL TRACEABILITY