Pyramax 10 zone HI PWR Pyramax 125/150 HI POWER HEATER S PURCHASER TO SUPPLY CIRCUIT BREAKER OR FUSED DISCONNECT SWITCH FOR: 240 Volts 350 Amperes 3 Phase 3 Wires 130 Kilovolt-amperes 50/60HZ Furnaces case must be ground…

Pyramax 10 zone STD
Pyramax 125/150 STD HEATER
S
PURCHASER TO SUPPLY CIRCUIT BREAKER OR FUSED DISCONNECT SWITCH FOR:
240 Volts 250 Amperes 3 Phase 3 Wires
95 Kilovolt-amperes 50/60HZ
Furnaces case must be grounded per local codes
Line Total htr Avg htr Typical
Voltages L1 L2 L3 Neutral Total KVA Power load [30%] oper. pwr.
200 173 173 184 n/a 64 56 17 24 not std offering
208 180 180 192 n/a 70 61 18 26
220 191 191 203 n/a 78 68 20 28
230 199 199 212 n/a 85 74 22 30
240 208 208 221 n/a 93 81 24 32
Typical Operating Power 32 KVA Typical Oper Pwr = Avg. Htr. Load + 0.8 x (6KVA+1.5KVA+2KVA)
Average heater load 24 KW Average heater load = 30% of Total Htr Load
Overtemp T/C's in zones
Pyramax 125/150 STD HEATER
S
PURCHASER TO SUPPLY CIRCUIT BREAKER OR FUSED DISCONNECT SWITCH FOR:
480 Volts 125 Amperes 3 Phase 3 Wires
95 Kilovolt-amperes 50/60HZ
Furnaces case must be grounded per local codes
Line Total htr Avg htr Typical
Voltages L1 L2 L3 Neutral Total KVA Power load [30%] oper. pwr.
440 95 95 101 n/a 78 68 20 28
460 100 100 106 n/a 85 74 22 30
480 104 104 111 n/a 93 81 24 32
Typical Operating Power 32 KVA Typical Oper Pwr = Avg. Htr. Load + 0.8 x (6KVA+1.5KVA+2KVA)
Average heater load 24 KW Average heater load = 30% of Total Htr Load
Overtemp T/C's in zones
Pyramax 125/150 STD HEATER
S
PURCHASER TO SUPPLY CIRCUIT BREAKER OR FUSED DISCONNECT SWITCH FOR:
415/240 Volts 160 Amperes 3 Phase 4 Wires
95 Kilovolt-amperes 50/60HZ
Furnaces case must be grounded per local codes
Line Total htr Avg htr Typical
Voltages L1 L2 L3 Neutral Total KVA Power load [30%] oper. pwr.
380/220 103 117 117 117 78 68 20 28
400/230 108 122 122 122 85 74 22 30
415/240 112 128 128 128 93 81 24 32
Typical Operating Power 32 KVA
Typical Oper Pwr = Avg. Htr. Load + 0.8 x (6KVA+1.5KVA+2KVA)
Average heater load 24 KW Average heater load = 30% of Total Htr Load
Overtemp T/C's in zones
LINE CURRENT- [AMPERES]
MAXIMUM LOAD DATA
LINE CURRENT- [AMPERES]
MAXIMUM LOAD DATA
LINE CURRENT- [AMPERES]
MAXIMUM LOAD DATA
52089671.xls
Prepared by Rich Tarczon
2/13/06
1 of 1
APPROVED
APPROVED
APPROVED
This is trial version
www.adultpdf.com

Pyramax 10 zone HI PWR
Pyramax 125/150 HI POWER HEATER
S
PURCHASER TO SUPPLY CIRCUIT BREAKER OR FUSED DISCONNECT SWITCH FOR:
240 Volts 350 Amperes 3 Phase 3 Wires
130 Kilovolt-amperes 50/60HZ
Furnaces case must be grounded per local codes
Line Total htr Avg htr Typical
Voltages L1 L2 L3 Neutral Total KVA Power load [30%] oper. pwr.
200 239 239 250 n/a 88 80 24 32 not std offering
208 249 249 260 n/a 96 87 26 34
220 263 263 275 n/a 107 97 29 37
230 275 275 288 n/a 117 106 32 39
240 287 287 300 n/a 127 115 35 42
Typical Operating Power 42 KVA Typical Oper Pwr = Avg. Htr. Load + 0.8 x (6KVA+1.5KVA+2KVA)
Average heater load 35 KW Average heater load = 30% of Total Htr Load
Overtemp T/C's in zones
Pyramax 125/150 HI POWER HEATER
S
PURCHASER TO SUPPLY CIRCUIT BREAKER OR FUSED DISCONNECT SWITCH FOR:
480 Volts 175 Amperes 3 Phase 3 Wires
130 Kilovolt-amperes 50/60HZ
Furnaces case must be grounded per local codes
Line Total htr Avg htr Typical
Voltages L1 L2 L3 Neutral Total KVA Power load [30%] oper. pwr.
440 132 132 138 n/a 107 97 29 37
460 138 138 144 n/a 117 106 32 39
480 144 144 150 n/a 127 115 35 42
Typical Operating Power 42 KVA Typical Oper Pwr = Avg. Htr. Load + 0.8 x (6KVA+1.5KVA+2KVA)
Average heater load 35 KW Average heater load = 30% of Total Htr Load
Overtemp T/C's in zones
Pyramax 125/150 HI POWER HEATER
S
PURCHASER TO SUPPLY CIRCUIT BREAKER OR FUSED DISCONNECT SWITCH FOR:
415/240 Volts 200 Amperes 3 Phase 4 Wires
130 Kilovolt-amperes 50/60HZ
Furnaces case must be grounded per local codes
Line Total htr Avg htr Typical
Voltages L1 L2 L3 Neutral Total KVA Power load [30%] oper. pwr.
380/220 145 159 159 159 107 97 29 37
400/230 152 166 166 166 117 106 32 39
415/240 158 173 173 173 127 115 35 42
Typical Operating Power 42 KVA
Typical Oper Pwr = Avg. Htr. Load + 0.8 x (6KVA+1.5KVA+2KVA)
Average heater load 35 KW Average heater load = 30% of Total Htr Load
Overtemp T/C's in zones
LINE CURRENT- [AMPERES]
MAXIMUM LOAD DATA
LINE CURRENT- [AMPERES]
MAXIMUM LOAD DATA
LINE CURRENT- [AMPERES]
MAXIMUM LOAD DATA
52089672.xls Rev:0
Prepared by Rich Tarczon
2/13/06
1 of 1
APPROVED
APPROVED
APPROVED
This is trial version
www.adultpdf.com

Pmax 10z Mechanical Utilities
Pyramax 125/150 (10 Zone) Mechanical Utility Requirement
s
Utility Size Pressure Nominal Flow Comments
N2 0.5 NPT 65-80 PSIG 30 SCFM See Note: 4
Air (optional) 0.5 NPT 65-80 PSIG 30 SCFM Air required only if optional dual inlet was purchased. See Note: 4
H20 Drain 0.5 NPT Open Drain 3 - 6.5 GPM See Notes: 4, 5
H2O Inlet 0.5 NPT 30-85 PSIG 3 - 6.5 GPM Water inlet temp required: 5 - 30 C (41 - 86 F) See Notes: 4, 5
Entrance Lip Vent Exhaust 5.0" Dia. 0.1 - 0.05 IWC 125 SCFM See Notes: 1,2,3
Exit Lip Vent Exhaust 5.0" Dia. 0.1 - 0.05 IWC 200 SCFM See Notes: 1,2,3
Notes:
1. Connect active exhaust directly to vent
2. Exhaust gas flows are based on a 3-1 entrainment ratios. Different entrainment ratios may be necessary. Consult you local HVAC specialist if necessary.
3. BTU recommends the use on filtration on customer's exhaust system to prevent the build up of effluents in the duct work.
4. Recommended supply line is 0.62" inside diameter. Larger diameters may be required for long supply lines.
5. BTU recommends 20 °C water for 400 °C application
s
Maximum Operating Temperature - 350 Degrees Celsius
Nominal Operating Temperature - 100 to 300 Degrees Celsius
52089673.xls Rev:0
Prepared by Rich Tarczon
2/13/06
1 of 1