APPLIED VOLTAGES 200 208 220 230 240 ZONE HEATE R AMPS TOTAL TOTAL AMPS TOTAL TOTAL A MPS TOTAL TOTAL A MPS TOTAL TOTAL AMPS TOTAL TOTAL LENGTH POSITION AMPS K W A MPS K W A MPS K W A MPS K W AMPS K W HIGH POWER HEATERS …

Pmax 10z Mechanical Utilities
Pyramax 125/150 (10 Zone) Mechanical Utility Requirement
s
Utility Size Pressure Nominal Flow Comments
N2 0.5 NPT 65-80 PSIG 30 SCFM See Note: 4
Air (optional) 0.5 NPT 65-80 PSIG 30 SCFM Air required only if optional dual inlet was purchased. See Note: 4
H20 Drain 0.5 NPT Open Drain 3 - 6.5 GPM See Notes: 4, 5
H2O Inlet 0.5 NPT 30-85 PSIG 3 - 6.5 GPM Water inlet temp required: 5 - 30 C (41 - 86 F) See Notes: 4, 5
Entrance Lip Vent Exhaust 5.0" Dia. 0.1 - 0.05 IWC 125 SCFM See Notes: 1,2,3
Exit Lip Vent Exhaust 5.0" Dia. 0.1 - 0.05 IWC 200 SCFM See Notes: 1,2,3
Notes:
1. Connect active exhaust directly to vent
2. Exhaust gas flows are based on a 3-1 entrainment ratios. Different entrainment ratios may be necessary. Consult you local HVAC specialist if necessary.
3. BTU recommends the use on filtration on customer's exhaust system to prevent the build up of effluents in the duct work.
4. Recommended supply line is 0.62" inside diameter. Larger diameters may be required for long supply lines.
5. BTU recommends 20 °C water for 400 °C application
s
Maximum Operating Temperature - 350 Degrees Celsius
Nominal Operating Temperature - 100 to 300 Degrees Celsius
52089673.xls Rev:0
Prepared by Rich Tarczon
2/13/06
1 of 1
APPROVED
APPROVED
APPROVED
This is trial version
www.adultpdf.com

APPLIED VOLTAGES
200 208 220 230 240
ZONE HEATE
R
AMPS TOTAL TOTAL AMPS TOTAL TOTAL
A
MPS TOTAL TOTAL
A
MPS TOTAL TOTAL AMPS TOTAL TOTAL
LENGTH POSITION AMPS K
W
A
MPS K
W
A
MPS K
W
A
MPS K
W
AMPS K
W
HIGH POWER HEATERS 14" T 17.32 A 34.63 A 6.9 KW 18.01 A 36.02 A 7.5 KW 19.05 A 38.1 A 8.4 KW 19.91 A 39.83 A 9.2 KW 20.78 A 41.56 A 10.0 KW
zones 1, 2, 9, and 10 B 17.32 A 18.01 A 19.05 A 19.91 A 20.78 A
LOW POWER HTRS 14" T 9.4 A 18.8 A 3.8 KW 9.8 A 19.6 A 4 KW 10.3 A 20.6 A 4.6 KW 10.8 A 21.6 A 5 KW 11.3 A 22.6 A 5.4 KW
zones 3 through 8 B 9.4 A 9.8 A 10.3 A 10.8 A 11.3 A
APPLIED VOLTAGES
440 460 480
ZONE HEATE
R
AMPS TOTAL TOTAL
A
MPS TOTAL TOTAL
A
MPS TOTAL TOTAL
LENGTH POSITION AMPS K
W
A
MPS K
W
A
MPS K
W
HIGH POWER HEATERS 14" T 9.52 A 19.05 A 8.4 KW 9.96 A 19.91 A 9.2 KW 10.39 A 20.78 A 10.0 KW
zones 1, 2, 9, and 10 B 9.52 A 9.96 A 10.39 A
LOW POWER HTRS 14" T 5.15 A 10.3 A 4.6 KW 5.4 A 10.8 A 5 KW 5.65 A 11.3 A 5.4 KW
zones 3 through 8 B 5.15 A 5.4 A 5.65 A
NOTES for HEATER DATA SHEET TABLE
S
KE
Y
FURNACE CONFIGUTATION
1. SELECT THE APPROPRIATE VOLTAGE COLUMN FOR HEATER AMPS AND KW RATINGS. T = TOP
2. FOR 3 PHASE 4 WIRE SYSTEMS REFER TO THE PHASE VOLTAGE. FOR EXAMPLE; B = BOTTOM
AT 380/220V USE THE 220V COLUMN L = LEFT
AT 400/230V USE THE 230V COLUMN R = RIGHT
AT 415/240V USE THE 240V COLUMN S = SIDE
C = CENTER
3. THE CALCULATIONS ARE BASED ON NOMINAL RESISTANCE AND VOLTAGE. THE
APPROXIMATED HOT RESISTANCE:
LOW PWR HATERS - 21.3 OHMS @240V
HIGH PWR HATERS - 11.5 OHMS @240V
TOLERANCE FOR THE HEATER RESISTANCE IS +/- 5% AND FOR VOLTAGE +/- 10%
APPROVALS DATE Title BTU International, Inc.
DRAWN RTARCZON FEB06 HEATER DATA SHEE
T
North Billerica, MA. 01862
~ ~ ~ ~ CHECK RTARCZON FEB06 PYRAMAX 150/125 Size Drawing No. REV
REV. Description Date Approved ENGR. RTARCZON FEB06 WITH HI-POWER HEATERS I
N
B 5241098 0
REVISIONS PROD. ZONES 1, 2 AND 9, 10 TOP/BOTTOM Scale --- Excel Database Sheet 1 of 1
PYRAMAX 150/125: 10 ZONES TOP & BOTTOM WITH HI-
POWER HEATERS IN ZONES 1, 2, 9, and 10 TOP & BOTTOM
APPROVED
APPROVED