Pmax 10z Mechanical Utilities Pyramax 125/150 (10 Zone) Mechanical Utility Requirement s Utility Size Pressure Nominal Flow Comments N2 0.5 NPT 65-80 PSIG 30 SCFM See Note: 4 Air (optional) 0.5 NPT 65-80 PSIG 30 SCFM Air…

Pyramax 10 zone HI PWR
Pyramax 125/150 HI POWER HEATER
S
PURCHASER TO SUPPLY CIRCUIT BREAKER OR FUSED DISCONNECT SWITCH FOR:
240 Volts 350 Amperes 3 Phase 3 Wires
130 Kilovolt-amperes 50/60HZ
Furnaces case must be grounded per local codes
Line Total htr Avg htr Typical
Voltages L1 L2 L3 Neutral Total KVA Power load [30%] oper. pwr.
200 239 239 250 n/a 88 80 24 32 not std offering
208 249 249 260 n/a 96 87 26 34
220 263 263 275 n/a 107 97 29 37
230 275 275 288 n/a 117 106 32 39
240 287 287 300 n/a 127 115 35 42
Typical Operating Power 42 KVA Typical Oper Pwr = Avg. Htr. Load + 0.8 x (6KVA+1.5KVA+2KVA)
Average heater load 35 KW Average heater load = 30% of Total Htr Load
Overtemp T/C's in zones
Pyramax 125/150 HI POWER HEATER
S
PURCHASER TO SUPPLY CIRCUIT BREAKER OR FUSED DISCONNECT SWITCH FOR:
480 Volts 175 Amperes 3 Phase 3 Wires
130 Kilovolt-amperes 50/60HZ
Furnaces case must be grounded per local codes
Line Total htr Avg htr Typical
Voltages L1 L2 L3 Neutral Total KVA Power load [30%] oper. pwr.
440 132 132 138 n/a 107 97 29 37
460 138 138 144 n/a 117 106 32 39
480 144 144 150 n/a 127 115 35 42
Typical Operating Power 42 KVA Typical Oper Pwr = Avg. Htr. Load + 0.8 x (6KVA+1.5KVA+2KVA)
Average heater load 35 KW Average heater load = 30% of Total Htr Load
Overtemp T/C's in zones
Pyramax 125/150 HI POWER HEATER
S
PURCHASER TO SUPPLY CIRCUIT BREAKER OR FUSED DISCONNECT SWITCH FOR:
415/240 Volts 200 Amperes 3 Phase 4 Wires
130 Kilovolt-amperes 50/60HZ
Furnaces case must be grounded per local codes
Line Total htr Avg htr Typical
Voltages L1 L2 L3 Neutral Total KVA Power load [30%] oper. pwr.
380/220 145 159 159 159 107 97 29 37
400/230 152 166 166 166 117 106 32 39
415/240 158 173 173 173 127 115 35 42
Typical Operating Power 42 KVA
Typical Oper Pwr = Avg. Htr. Load + 0.8 x (6KVA+1.5KVA+2KVA)
Average heater load 35 KW Average heater load = 30% of Total Htr Load
Overtemp T/C's in zones
LINE CURRENT- [AMPERES]
MAXIMUM LOAD DATA
LINE CURRENT- [AMPERES]
MAXIMUM LOAD DATA
LINE CURRENT- [AMPERES]
MAXIMUM LOAD DATA
52089672.xls Rev:0
Prepared by Rich Tarczon
2/13/06
1 of 1
APPROVED
APPROVED
APPROVED
This is trial version
www.adultpdf.com

Pmax 10z Mechanical Utilities
Pyramax 125/150 (10 Zone) Mechanical Utility Requirement
s
Utility Size Pressure Nominal Flow Comments
N2 0.5 NPT 65-80 PSIG 30 SCFM See Note: 4
Air (optional) 0.5 NPT 65-80 PSIG 30 SCFM Air required only if optional dual inlet was purchased. See Note: 4
H20 Drain 0.5 NPT Open Drain 3 - 6.5 GPM See Notes: 4, 5
H2O Inlet 0.5 NPT 30-85 PSIG 3 - 6.5 GPM Water inlet temp required: 5 - 30 C (41 - 86 F) See Notes: 4, 5
Entrance Lip Vent Exhaust 5.0" Dia. 0.1 - 0.05 IWC 125 SCFM See Notes: 1,2,3
Exit Lip Vent Exhaust 5.0" Dia. 0.1 - 0.05 IWC 200 SCFM See Notes: 1,2,3
Notes:
1. Connect active exhaust directly to vent
2. Exhaust gas flows are based on a 3-1 entrainment ratios. Different entrainment ratios may be necessary. Consult you local HVAC specialist if necessary.
3. BTU recommends the use on filtration on customer's exhaust system to prevent the build up of effluents in the duct work.
4. Recommended supply line is 0.62" inside diameter. Larger diameters may be required for long supply lines.
5. BTU recommends 20 °C water for 400 °C application
s
Maximum Operating Temperature - 350 Degrees Celsius
Nominal Operating Temperature - 100 to 300 Degrees Celsius
52089673.xls Rev:0
Prepared by Rich Tarczon
2/13/06
1 of 1
APPROVED
APPROVED
APPROVED
This is trial version
www.adultpdf.com

APPLIED VOLTAGES
200 208 220 230 240
ZONE HEATE
R
AMPS TOTAL TOTAL AMPS TOTAL TOTAL
A
MPS TOTAL TOTAL
A
MPS TOTAL TOTAL AMPS TOTAL TOTAL
LENGTH POSITION AMPS K
W
A
MPS K
W
A
MPS K
W
A
MPS K
W
AMPS K
W
HIGH POWER HEATERS 14" T 17.32 A 34.63 A 6.9 KW 18.01 A 36.02 A 7.5 KW 19.05 A 38.1 A 8.4 KW 19.91 A 39.83 A 9.2 KW 20.78 A 41.56 A 10.0 KW
zones 1, 2, 9, and 10 B 17.32 A 18.01 A 19.05 A 19.91 A 20.78 A
LOW POWER HTRS 14" T 9.4 A 18.8 A 3.8 KW 9.8 A 19.6 A 4 KW 10.3 A 20.6 A 4.6 KW 10.8 A 21.6 A 5 KW 11.3 A 22.6 A 5.4 KW
zones 3 through 8 B 9.4 A 9.8 A 10.3 A 10.8 A 11.3 A
APPLIED VOLTAGES
440 460 480
ZONE HEATE
R
AMPS TOTAL TOTAL
A
MPS TOTAL TOTAL
A
MPS TOTAL TOTAL
LENGTH POSITION AMPS K
W
A
MPS K
W
A
MPS K
W
HIGH POWER HEATERS 14" T 9.52 A 19.05 A 8.4 KW 9.96 A 19.91 A 9.2 KW 10.39 A 20.78 A 10.0 KW
zones 1, 2, 9, and 10 B 9.52 A 9.96 A 10.39 A
LOW POWER HTRS 14" T 5.15 A 10.3 A 4.6 KW 5.4 A 10.8 A 5 KW 5.65 A 11.3 A 5.4 KW
zones 3 through 8 B 5.15 A 5.4 A 5.65 A
NOTES for HEATER DATA SHEET TABLE
S
KE
Y
FURNACE CONFIGUTATION
1. SELECT THE APPROPRIATE VOLTAGE COLUMN FOR HEATER AMPS AND KW RATINGS. T = TOP
2. FOR 3 PHASE 4 WIRE SYSTEMS REFER TO THE PHASE VOLTAGE. FOR EXAMPLE; B = BOTTOM
AT 380/220V USE THE 220V COLUMN L = LEFT
AT 400/230V USE THE 230V COLUMN R = RIGHT
AT 415/240V USE THE 240V COLUMN S = SIDE
C = CENTER
3. THE CALCULATIONS ARE BASED ON NOMINAL RESISTANCE AND VOLTAGE. THE
APPROXIMATED HOT RESISTANCE:
LOW PWR HATERS - 21.3 OHMS @240V
HIGH PWR HATERS - 11.5 OHMS @240V
TOLERANCE FOR THE HEATER RESISTANCE IS +/- 5% AND FOR VOLTAGE +/- 10%
APPROVALS DATE Title BTU International, Inc.
DRAWN RTARCZON FEB06 HEATER DATA SHEE
T
North Billerica, MA. 01862
~ ~ ~ ~ CHECK RTARCZON FEB06 PYRAMAX 150/125 Size Drawing No. REV
REV. Description Date Approved ENGR. RTARCZON FEB06 WITH HI-POWER HEATERS I
N
B 5241098 0
REVISIONS PROD. ZONES 1, 2 AND 9, 10 TOP/BOTTOM Scale --- Excel Database Sheet 1 of 1
PYRAMAX 150/125: 10 ZONES TOP & BOTTOM WITH HI-
POWER HEATERS IN ZONES 1, 2, 9, and 10 TOP & BOTTOM
APPROVED
APPROVED
APPROVED
This is trial version
www.adultpdf.com