TM2965.Functional Specification of Board Data Change without Stop.pdf - 第4页
SMT Software En gineering Group IMOperations YAMAHAMOTORCO.,LTD. MD OC-SOFT50119 4/8 5. Operati on Metho d of Cha nging Boa rd Dat a 5.1 Change in the w hole lane st ate is RESET Thereisnoch…

SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50119
3/8
4. Setting method
4.1 Setting at “Machine”
Set[Machine]–[MachineInformation]–[OptionSetting]–[DetailSetting]–[BoardDataChange
withoutStop]to“ON”(seeFig4.1).
Fig4.1[DetailSetting]screen

SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50119
4/8
5. Operation Method of Changing Board Data
5.1 Change in the whole lane state is RESET
Thereisnochangeintheboarddatachangingmethodinthestateofwholelanereset.
5.2 Change in the one side lane state is RUNNING
Resetalanewhichyouwanttochangeitsboarddata,andselectthenewonefromtheBoard
data select screen. You can select the board data even while the other lane is running (see
Fig.5.1).
Fig5.1[Boarddataselect]screen
Boarddataselectisavailableevenwhentheotherlaneisrunning.
Boarddataisselectableonlyonthelaneinaresetstate.

SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50119
5/8
Whenonesidelaneisautorunning,therearetworestrictionsasfollows.
A) Whenboarddatachangeisexecutedwhiletheothersidelaneismounting,thelanestate
becomes “RESERVED” (See Fig5.2). After finishing mounting on the one side lane, the
boarddatachangeisexecuted.
Fig5.2Thestateof[RESERVED]
B) Iftheboarddatatochangehasanerror,thefollowingerrormessageisdisplayed,andthe
board data change process is canceled (See Fig5.3). To check the error detail, please
executeeitherofthefollowingprocedures.
Resetalllanes,andchangetheboarddataagain.
OpentheBoardEditor,andexecutedatacheckat[Tool]–[DataCheck].
Fig5.3Anerrormessage“Ea24553:BoardDataError”