2 Assembly Instructions Tape cutter freque ncy controller SIPLACE S / F / HS / C- / HF- / X- / D-series Controller 02/2008 Edition 22 : Connect the existing connecto rs of ele ctronic valve and sens or to the n ew tape c…

100%1 / 26
Controller 2 Assembly Instructions Tape cutter frequency controller SIPLACE S / F / HS / C- / HF- / X- / D-series
02/2008 Edition
21
: Attach the cover on the new tape cutter frequency on top of the control board box.
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Cover
Box
2 Assembly Instructions Tape cutter frequency controller SIPLACE S / F / HS / C- / HF- / X- / D-series Controller
02/2008 Edition
22
: Connect the existing connectors of electronic valve and sensor to the new tape cutter fre-
quency controller board.
Watch on for the agreement of the numbers between connector and PCB board.
Connect a pair of numbers.
2
Please be careful the electronic valve connector direction. Because the connector can connect
reverse direction. 2
2
2
: Conect the red access cable (+) of the connector on pin (+) of the connector socket at the PCB
board.
2
2
+ mark
connectors
Controller 2 Assembly Instructions Tape cutter frequency controller SIPLACE S / F / HS / C- / HF- / X- / D-series
02/2008 Edition
23
2.5 SITEST
: Start SITEST.
: Do the cutter control moving test by SITEST.
: In case of failure reject and check the connector on both control units.
2
2
2