Empty Tape Duct.pdf - 第13页

SIPLACE 1 Assembly instructions Special design Empty Tape Duct SIPLACE HS-60 / D4 08/2007 Edition 13 : Unscrew the 4 screws holding the empty ta pe duct and re move it from the machine. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Em…

100%1 / 18
1 Assembly instructions Special design Empty Tape Duct SIPLACE HS-60 / D4 SIPLACE
08/2007 Edition
12
: Remove the feeder cover flap from the empty tape guide channel.
For easy removal loosen the 4 screws holding the flap to the holder in the component table
lock.
1
1
: Remove the reject device nozzle changer.
1
NOTE:
The four screws holding the flap to the
side holders can be loosened for easy
removal of feeder cover flap
Feeder cover flap
Feeder cover flap
SIPLACE 1 Assembly instructions Special design Empty Tape Duct SIPLACE HS-60 / D4
08/2007 Edition
13
: Unscrew the 4 screws holding the empty tape duct and remove it from the machine.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Empty tape
guide channel
1 Assembly instructions Special design Empty Tape Duct SIPLACE HS-60 / D4 SIPLACE
08/2007 Edition
14
1.8 Installing the Special design Empty tape duct
: Fix the Reject device nozzle changer to the Special design Empty tape duct.
: Mount and fix the Special design Empty tape duct on the machine and route the cable properly.
1
1
: Reattach the component table lock to the Special design Empty tape duct.
: Fix the gas spring to the component Flap.
: Fix the component reject box.
: Fix the Nozzle changer to the Special design Empty tape duct.
1
Special design
Empty tape duct
Cable to be routed
properly