Retrofit Instructions Splice Detection Table Controller S / F 07/2002 Edition 21 : At the back right cor ner of the OEM co ntroller , unplu g the oran ge power c onnector pl ug tha t plugged i nto the co ntrolle r . Also…

Retrofit Instructions Splice Detection Table Controller S / F
07/2002 Edition
20
,QVWDOODWLRQRIWKH6SOLFH'HWHFWLRQ7DEOH&RQWUROOHU
.LW
: This kit requires changing out of the stock controller module with the new module. There are
several different mounting methods for the OEM table controller and the subsequent Splice De-
tect Table Controller will mount in the identical fashion as the original.
: On the right side of the feeder table, cut the tie straps that hold the existing cable to the formed
metal extension arm (see Fig. 12 - 1).
Depending on the version of the table the cables are fixed in a U-profile. In this case please cut
the tie straps and loosen the cables in the same way.
existing cable wire ties

Retrofit Instructions Splice Detection Table Controller S / F
07/2002 Edition
21
: At the back right corner of the OEM controller, unplug the orange power connector plug that
plugged into the controller. Also use the flat blade screwdriver to remove the two wire clamp
screws that attach this wire to the back of the existing box, as shown in Fig. 12 - 2.
: When dealing with the feeder table that has mounting holes through the riser blocks, remove
the cap plugs (see Fig. 12 - 3) that hide the 4 table controller mounting bolts. Remove the four
mounting bolts while holding or supporting the box in the front to prevent the existing box from
falling.
: Install the new box using the existing hardware in a similar fashion.
Wire clamp Power plug
Cap plugs

Retrofit Instructions Splice Detection Table Controller S / F
07/2002 Edition
22
: When retrofitting the ‘bellows’ type feeder table, the mounting method for the controller is two
angle brackets at the back of the controller.
: Attach the new box by removing these four bolts and using the same hardware to attach the
new box (see Fig. 12 - 4).
: Using the orange power jumper plug in the kit, plug this jumper into the plug areas to the right
and above/below each other as shown in Fig. 12 - 5.
: Plug the single existing power cable from the transformer into the single plug area on the left,
and reattach the wire clamp to hold the gray power cable as shown.
Mounting angle
bracket
Mounting bolts
original power plug
power
jumper
plugs