80S-20贴片机.pdf - 第137页

SIPLACE 80S -20/F4/F4-6/F5 Service Manual 5 Gantries Edition 09/99 5.7 Exchanging the X-/Y-Trailing Cable 5 - 29 Fig. 5.7.5 O n S-20: Making Gantry B oard Accessible to Exchange of Trailing Cable at Gantry 2 Key: 1) Mac …

100%1 / 483
5 Gantries SIPLACE 80S-20/F4/F4-6/F5 Service Manual
5.7 Exchanging the X-/Y-Trailing Cable Edition 09/99
5 - 28
Fig. 5.7.4 80 S-20: Layout of the Trailing Cable at Gantry 1 and 2, Overviews of the Machine
An SIPLACE 80 F4/F5 and S-20:
Holt onto the protective doors of the component feeding on the side that the trailing cable is going to
be removed.
Loosen the 2 M6 screws (size 5 Allen wrench) on the small end of the side guard (see Fig. 5.7.5 -> 4
and 5) and remove the protective doors.
Loosen some of the screws fastening the cover plate at the front (loosen 4 out of 6 screws with size 3
Allen wrench: see Fig. 5.7.5 -> 2 und 3). The cover plate does not have to be completely removed.
WARNING O O
Have a 2nd person to assist you in the following disassembly of the side guard. The part is heavy.
Do not put your foot under it.
Instruct the 2nd person to hold onto the side guard while you loosen the six M6 screws on the side
guard (see Fig. 5.7.5 -> 4 and 5).
SIPLACE 80S-20/F4/F4-6/F5 Service Manual 5 Gantries
Edition 09/99 5.7 Exchanging the X-/Y-Trailing Cable
5 - 29
Fig. 5.7.5 On S-20:
Making Gantry Board Accessible to Exchange of Trailing Cable at Gantry 2
Key:
1) Machine base doors 2) Cover plate
(servo cabinet / terminal panel Y0903)
3) Six M4 socket head cap screws (round head) 4) Side guard
5) Six M6 socket head cap screws 6) Buffer
7) Fastener for buffer: One M8 socket cap screw 8) Grounding cable (behind side guard)
Bend the side guard out slightly and pull the cable lug of the ground cable out of the socket at the bottom
inside the side guard.
Set the side guard and the machine doors down such that these components do not fall over and are not in
the way during the following steps.
Hold onto the buffer and loosen the M8 socket hex cap screw (see Fig. 5.7.5 -> 6 and 7).
Pull the bracket and buffer off the centering pins (Details: see Fig. 5.7.1).
Manually push the pertinent placement head forward over the corresponding component feeding so that
the trailing cable is readily accessible.
Proceed to the steps in the next section if you only have to exchange the protective hose.
5 Gantries SIPLACE 80S-20/F4/F4-6/F5 Service Manual
5.7 Exchanging the X-/Y-Trailing Cable Edition 09/99
5 - 30
5.7.6.2 Y-Gantry Area: Preparing Ribbon Cable Package for Removal
WARNING O O
During the following steps in the area of the gantry board, comply with regulations on ESDs (see Section 1 of
this service manual).
Fig. 5.7.6 Removing Ribbon Cable Ties, Disconnecting Plug-In Connections on the board
Carefully remove the ties on the ribbon cable package (see Fig. 5.7.6 -> 1).
Disconnect the plug-in connectors of the ribbon cable coming from the trailing cable (see Fig. 5.7.6 ->
2). The markings on the board and the cables define the allocations.
3 cable
ties
Gantry
board
Side guard
(dismantled)