Installation Manual, Station Software Version 602.01 Edition 06/2006 4.9.2 BIOS settings The required BIOS settings are supplied as an ISO im age on the installation CD. This image can be used to create a bootable CD wit…

100%1 / 120
Installation Manual, Station Software Version 602.01 Edition 06/2006
57 of 60
4.9.1.3 Installing the RMOS
The RMOS is always installed under menu guidance. The following selection is displayed after the
machine controller has booted from CD:
DO YOU WANT TO CONTINUE RMOS INSTALLATION ?
[C] CONTINUE [P] PREPARE HARDDISK
[R] REBOOT SYSTEM
[T] TERMINATE BATCH PROCESS (Change to DOS)
PRESS KEY TO CONTINUE [C,R,T,P]?
Enter 'P' to create the partitions on the hard disk. The system is then booted.
When the menu shown above appears again, press 'C' (Continue) to actually install the RMOS.
The basic RMOS installation is now complete. The station software can be installed.
4.9.1.4 Restore initial configuration
Remove RMOS installation CD from the USB CD drive.
Remove the keyboard from the machine controller and connect it to the station computer.
Switch video multiplexer to SR1.
Disconnect the USB cable from the USB CD drive and the machine controller.
Press <Ctrl><Alt><Del> to warm start the machine controller.
Installation Manual, Station Software Version 602.01 Edition 06/2006
4.9.2 BIOS settings
The required BIOS settings are supplied as an ISO image on the installation CD. This image can be used to
create a bootable CD with suitable CD writing software on a PC with a CD writer. This CD can in turn be
used to automatically make the BIOS settings.
Procedure:
Create the CD 'CPU420_MC_BIOS_Settings'.
Remove the keyboard from the station computer and connect it to the machine controller.
Switch the video multiplexer to SR2/MC.
Insert the CD 'CPU420_MC_BIOS_Settings' in the USB CD drive and connect the drive to the machine
controller using a USB cable.
Reboot the machine controller and follow the BIOS setting instructions.
Restore the initial configuration (see section
4.9.1.4).
4.9.3 Manual installation of the machine controller software
The following step can be omitted if the station software is installed. (The MC Distributor is called during the
course of the station software installation.)
Open the Start menu and select Programs Æ Siplace Æ MC Distributor. The installation is started.
Follow the instructions on screen.
58 of 60