TM1794_Auto Cleaning Detail Setting.pdf - 第3页
SMT Software Engineering Group IM Operations YAMAHA MOTOR CO. , LTD MDOC-SOFT5007 1 3 3. Settings The settings to use this function are as follows. 3.1. In the case of “Controlled in the Boa rd” All of cleaning detail se…

SMT Software Engineering Group
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50071
2
1. Introduction
The target model and the version are as follows.
Table1.1 Target model and target version
Item Object Remarks
Target model YSP
Target version VGOS V3.21STD R1.000 or later
Y.FacT V1.21STD R1.000 or later
2. Summary
This function enables detail settings for the cleaning operation sequence.
Each forward or backward cleaning movement can be counted as one sequence. The
following parameter can be set for every sequence.
1. Cleaning Type (Wet/Dry)
2. Cleaning Speed
3. Vacuum (Use/Not Use)
This function does not support “TXT” type board data. Please save with “YGZ” type
board data in order to enable this function.

SMT Software Engineering Group
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50071
3
3. Settings
The settings to use this function are as follows.
3.1. In the case of “Controlled in the Board”
All of cleaning detail settings is set in “Cleaning Detail Setting” window. Please tap [Print]
– [Cleaner] – [Detail Setting] button and open the “Cleaning Detail Setting” window.
(Fig.3.1)
In “Cleaning Detail Setting” window, ten cleaning sequences (five round trip) can be set
at a maximum in each “Controlled in the board” tab(Four kinds of ”Controlled in the Board
1”– “Controlled in the Board 4” tab).
Input the cleaning execution interval to “Detail Auto Interval” . And set “Cleaning Type”,
“Speed” and “Vacuum” of each sequence.
When “None” is set on “Cleaning Type” cell, the following cleaning sequences are not
executed. When “0” is set on “Detail Auto Interval”, the following “Controlled in the Board”
tabs are invalid.
Fig.3.1 [Controlled in the Board] tab in “Cleaning Detail Setting” window
If “0” is set, following “Controlled in the Board 2” tabs are invalid.
The settings following No.6 are invalid because
“
None
”
is set.

SMT Software Engineering Group
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50071
4
Table3.1 Setting items in “Cleaning Detail Setting” window
Item Default
value
Input range Content
Detail Auto
Interval (Board)
0 0 - 9999 (Setting only for “Controlled in the Board”)
Set the cleaning frequency by the number of
board.
When “0” is set, the following “Controlled in the
Board” tabs are invalid.
Cleaning Type Dry Dry/
Wet/
None
“Dry”: Clean only with gauze
“Wet”: Clean with gauze and solvent
“None”: The following cleaning sequence is not
executed.
Speed (%) 100 1 - 100 Set the speed of cleaning unit at the cleaning.
(Following “Speed (mm/sec)” is linked with this
value)
Speed (mm/sec) 225 1 - 225 Set the speed of cleaning unit at the cleaning.
(Above “Speed (%/sec)” is linked with this
value)
Vacuum Use Use/
Not Use
“Use”: At the cleaning, mask is vacuumed
while cleaning unit moves.
“Not Use”: At the cleaning, mask is not
vacuumed while cleaning unit moves.
[Warning]
When vacuum is used in wet cleaning, solvent
spitted out dries. In this case, [Ea8816: DATA
CHECK WARNING] is displayed after selecting
a board data. Then change the settings.