2 Assembly instructions Splice De tection Basic Package SIPLACE HS-50 Sp lice Detection Basic Package HS-50 03/2008 Edition 24 : Connect the power supp ly cable for the hub (003 68322-01) to the main distributor . Connec…

100%1 / 30
Splice Detection Basic Package HS-50 2 Assembly instructions Splice Detection Basic Package SIPLACE HS-50
03/2008 Edition
23
: Replace the distance piece with the mount for the hub, then reinstall the hub and contact plug.
2
Abb. 2.11 - 2 Distance piece
2
: Use the serial cable to connect the hub to the free COM port on the station computer.
2
Abb. 2.11 - 3 Distributor sector 4
2
: Detach the cover for the sector 4 distributor (see Fig. 16 - 3).
2
distance piece
sector 4
2 Assembly instructions Splice Detection Basic Package SIPLACE HS-50 Splice Detection Basic Package HS-50
03/2008 Edition
24
: Connect the power supply cable for the hub (00368322-01) to the main distributor. Connect
GND (white or blue) at X101-PE and 15 V (brown) at X101-16b (see Fig 2.11 - 4).
2
Abb. 2.11 - 4 Main distributor
2
2
2
2
2
2
2
2
+ 15 Volt
GND
Splice Detection Basic Package HS-50 2 Assembly instructions Splice Detection Basic Package SIPLACE HS-50
03/2008 Edition
25
: Route the power supply cable correctly, and plug into the power supply socket for the hub (see
Fig. 16 - 5).
2
Abb. 2.11 - 5 Power supply socket
2
2.7.2 Connecting to the table controller (TC)
: Detach the covers from the sector 1, 2, 3 and 4 distributors.
: Replace the 4 covers with the new covers that allow the cables to be run from the hub to the
TC.
: Then fix the connecting cables:
Long CAT 5 cables (item no. 00368249-01) to the covers of sector 2 and 3
Short CAT 5 cables (item no. 00368250-01) to the covers of sector 1 and 4.
2
It is essential to start laying the cables from outside the panel. Do NOT start at the hub. 2
2
2
2
2
serial port
table 1 ... 4 power supply