00198586-02_JC_PMWF2_TX_V2_EN.pdf - 第21页

4 WF 2 TX-Series V2 Maintenance Remove the C&P20x to be maintained 3 min 1 / 2 C A U T I O N !  R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n…

100%1 / 52
www.asm-smt.com
4 WF 2 TX-Series V2 Maintenance Remove the C&P20x to be maintained 3 min 1 / 2
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T7, T8, T9, T94, T95
Wear Part: Consumables:
www.asm-smt.com
1 Move the gantry with the head to be main-
tained to the end limit.
2 Put on the component sensor protection. 3 Move the gantry with the head to be main-
tained to a good working position.
4 Unplug the exhaust hose. 5 Unplug the compressed air connections
from the head.
6 Remove the protection cover.
4 WF 2 TX-Series V2 Maintenance Remove the C&P20x to be maintained 3 min 2 / 2
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T7, T8, T9, T94, T95
Wear Part: Consumables:
www.asm-smt.com
7 Unplug the two ribbon cables. 8 Open the camera cable clip. 9 Release the plug lock and unplug the two
camera cables.
10 Loosen the 4 screws fixing the head. 11 Take the head from the hook. 12 Put the head into the transport container.