13 WF 2 TX-Series V2 Maintenance Calibrate the maintained C&P20x 3 min 1 / 4 C A U T I O N ! R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n a…

www.asm-smt.com

13 WF 2 TX-Series V2 Maintenance Calibrate the maintained C&P20x 3 min 1 / 4
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T2, T4, T100
Wear Part:
W25
Consumables:
www.asm-smt.com
1 Open the cover. 2 Insert the calibration tool into the pocket. 3 Close the cover.
4 Click on "Settings and options". 5 Click on "User settings". 6 Click on "Machine service".

13 WF 2 TX-Series V2 Maintenance Calibrate the maintained C&P20x 3 min 2 / 4
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T2, T4, T100
Wear Part:
W25
Consumables:
www.asm-smt.com
7 Click on "Machine calibration". 8 Click on "Fast hardware exchange". 9 Click on "Head exchange".
10 Select the head to be calibrated. 11 Select "Brief calibration" if possible. 12 Click on "Next".