1. Head Module Ver. Date CP45 CP45NEO 00 2004/11 O O 1-1 Fig.1-14-3 Blow Setting Blow Adjust Valve Blow flow direction Sol-vave Air Distributor Module Fitting DIsassemble Hose

100%1 / 37
1. Head Module
Ver. Date CP45
CP45NEO
00 2004/11 O O
1-1
1-14. Blow pressure Check
*Tools
a) Blow Setting Jig
*Part
a)
1) Blow Setting Specification : 0.13 (+,-)0.02 Mpa
2) Setting Procedure
2-1) Connect Power Connector of Fixture to Stick Feeder Connector of the Front of Equipment
(Fig 1-14-1)
Be Sure to Connect to Power Connector for Stick Feeder(Do not Use Connector for Camera)
2-2) Check the Initial Condition of Fixture (Fig 1-14-2)
- Select UNIT => 'M' (Mpa Unit)
- Press SET Button to Check if the Output of Initial Condition is '0'
- At this Time, Turn 'SET' Dial to '0' if the Output is not '0'
2-3) Separate Hose(Outside Diameter 4mm) Connected to Blow Adjustment Valve of Air
Distributor Module (Fig 1-14-3)
2-4) Connect the Separated Hose to the Output of Fixture and Connect the Hose Attached at
Fixture to the Back of Blow Adjustment Valve (Fig 1-14-3)
2-5) Adjust Blow Adjustment Valve to Set Fixture Output to be 0.13Mpa
2-6) After Adjustment, Fasten the Fixing Nut of Blow Adjustment Valve to Maintain the Set Value
2-7) The Blow Value Set when Equipment was Shipped is Generally Applied Optimal Value, but
Blow Value can be Adjusted to be Used Depending on User's Condition
POWER CONNECTOR
for STICK FEEDER
Power for jig
Select "
M
"inUNIT
(Mega Pascal)
Button for Origin
Adjust dial for origin (Zero setting)
Fig.1-14-1 Power connector for jig
Fig.1-14-2 Initailizing for Jig
1. Head Module
Ver. Date CP45
CP45NEO
00 2004/11 O O
1-1
Fig.1-14-3 Blow Setting
Blow Adjust Valve
Blow flow direction
Sol-vave
Air Distributor
Module
Fitting
DIsassemble
Hose
1. Head Module
Ver. Date CP45
CP45NEO
00 2004/11 O O
1-1
1-15. Vacuum Level Check
*Tools
a)
*Part
a)
1) Vacuum Check Procedure
1-1) Check at Diagnosis => Vacuum(F5)
1-2) Install Nozzle(CN040, TN040) at Nozzle Holder and Measure with Only Measuring Head
Vacuum On
1-3) Specification : over 600mmHg
2) Check Procedure in Case Vacuul Level is Entirely Unsatisfactory for the Standard
2-1) Check Main Air Pressure : 4.5 ~5.5 kgf/cm^2
- Check if Air Filter(Main) is Contaminated and Replace if Necessary
2-2) Vacuum pump
- Separate Filter(Vacuum Pump) to Clean and Replace if Necessary
- If Foreign Substance and Contamination are Serious, Replace Vacuum Pump
Especially, be Careful not to Apply Excessive Load when Fastening or Separating Fitting
(Look Out Damage)
3) Check Procedure in Case Vacuul Level by Head is Unsatisfactory for Standard
3-1) Separate Solenoid Valve(Air distributor Module) to Clean and Replace if Necessary
3-2) Separate Filter(Air distributor Module) to Clean and Replace if Necessary
=> There are Two Sorts of Filters:External and Internal Filters
Refer Cleaning Procedure of Manual for External One and Next Page for Internal One.
Fig.1-15-1 Vacuum Filter in Air Distributor