INTERCHANGEABLE UNDER SCREEN CLEANER MODULE
OVERVIEW
Chapter Issue 6, Jan 17 Technical Reference Manual 25.3
ASM only recommend the DEK-PRO and the DEK-PRO XF (Environmentally
Friendly) USC solutions to be used with the under screen cleaner. The following
are available from ASM:
NOTE
The following solvents MUST NOT be used in the under screen cleaner unit,
however, this list is not complete and does not mean that any solvent not
mentioned is compatible, with DEK machines.
Rosstech 106 FE
Rosstech 162 ND
Acetone
Iso-Propyl Alcohol (IPA)
Vacuum Filtration The vacuum filtration unit extracts solvent fumes and draws excess print
material onto the paper. Vacuum filtration is optional and may be one of the
following types:
Vacuum filtration is optional and may be one of the following types:
VF35i Vacuum Filtration Unit
VF30 Vacuum Filtration Unit (Type 5 machine only)
VF25 Vacuum Filtration Unit
VF10 Venturi Vacuum Filtration Unit
NOTE
For information on the removal and replacement of the filters, refer to the
Preventive Maintenance manual.
Description 1 Litre 5 Litre 20 Litre
DEK-PRO 173483 173485 431093
DEK-PRO XF 431513 431514 -
INTERCHANGEABLE UNDER SCREEN CLEANER MODULE
OVERVIEW
25.4 Technical Reference Manual Chapter Issue 6, Jan 17
Figure 25-1 Vacuum Option
VF35i Vacuum
Filtration Unit
The onboard VF35i vacuum filtration unit is protected by two circuit breakers on
the front panel of the base unit. A 15A (for 115V) and an 8A (for 230V) which
can be reset by pressing the circuit breaker button covered by a clear plastic
protector. For safety, the voltage selector control knob is removed from the
switch and bolted to the fan housing. The VF35i vacuum filtration unit has a
three position mechanical air flow adjuster to regulate the air flow as follows:
Maximum (full air flow)
Medium (half air flow approximately)
Minimum (15% of full air flow approximately)
Screen Cleaner Connection
Screen Cleaner Mount
Vacuum Connection
Telescopic Tube
Machine Mount
INTERCHANGEABLE UNDER SCREEN CLEANER MODULE
OVERVIEW
Chapter Issue 6, Jan 17 Technical Reference Manual 25.5
VF30 Vacuum
Filtration Unit
The onboard VF30 vacuum filtration unit is protected by either a 10A (for 115V
units) or 5A (for 230V units) circuit breaker.
VF25 Vacuum
Filtration Unit
The onboard VF25 vacuum filtration unit is protected by either a 10A (for 115V
units) or 5A (for 230V units) circuit breaker.
VF10 Vacuum
Filtration Unit
The onboard VF10 Venturi Vacuum Filtration Unit, located in the front of the
machine frame, uses compressed air to create a vacuum.