TECHNICAL REFERENCE APPENDIX CALIBRATIONS Chapter Issue 1 June 15 Appendix to Micron Technical Manuals 3.51 MMI T ouchscreen Calibration T o recalibrate the touchscreen carry out the following procedure: 1. T o access th…

100%1 / 165
TECHNICAL REFERENCE APPENDIX
CALIBRATIONS
3.50 Appendix to Micron Technical Manuals Chapter Issue 1 June 15
The following window is displayed:
17.Select Confirm to save the new print height.
18.Select Cancel to close the Set Reference Vision Height window.
19.Close the front printhead cover.
20.Press the System button.
21.Select Exit.
22.Select Exit.
23.Select Back.
24.Carry out the Squeegee Reference Height calibration, Squeegee chapter
refers.
Please confirm the following:
The board clamps are not lifting the stencil.
When the part of the stencil that is over the board
clampsispressed, there is noperceptiblemovement.
To adjust the elevation of the board clamps, press
Cancel. Use Incr. And Decr. to alter the value of print
height. Use Move
to apply
the current value of print
height.
Set Reference Vision Height
TECHNICAL REFERENCE APPENDIX
CALIBRATIONS
Chapter Issue 1 June 15 Appendix to Micron Technical Manuals 3.51
MMI
Touchscreen
Calibration
To recalibrate the touchscreen carry out the following procedure:
1. To access the Start button on the Windows task bar, press the Windows
key.
2. Select Programs, Touchscreen and 4pts Cal.
3. Follow the on screen instructions.
4. Touchscreen calibration is now complete.
5. Restore the DEK program.
SEMI 2
TECHNICAL REFERENCE APPENDIX
PREVENTIVE MAINTENANCE
3.52 Appendix to Micron Technical Manuals Chapter Issue 1 June 15
PREVENTIVE MAINTENANCE
The maintenance engineer should complete the following information boxes
as a permanent record of the machine details.
Machine Serial Number
Line Number
Customer
Engineer