00193903-02.pdf - 第16页

8 External power supply for SIPLACE HF-Series / D3 component trolley SIPLACE HF-series / D3 06/2006 Edition 16 1.1 Safety instructions DANGER Make sure that no one is working on th e connec ted compo nent trolley when yo…

100%1 / 26
SIPLACE HF-series / D3 8 External power supply for SIPLACE HF-Series / D3 component trolley
06/2006 Edition
15
8 External power supply for SIPLACE
HF-Series / D3 component trolley
8.1 External power supply for HF component trolley
(03009867-02), item number: 00119681-01)
Qty Designation Part no.:
- 1 power supply for 88...264 V AC (WxDxH = 180x360x210 mm) 03009868-02
- 1 power supply cable 230 V AC (EU 3x0.75 mm
2
, l =2.0 m) 00308240-01
- 1 power supply cable 125 V AC (US 3x18 AWG, l = 2.0 m) 03011615-01
- 2 integral fuses 6.30 A MT 03011614-01
- 1 enclosed pneumatic coupling 00351963-01
- 1 cable to power the component trolley 03006765-01
- 2 enclosed fuses 6.30 A MT for combination mains connector 03011614-01
8
Fig. 1 Scope of supply
a Power supply for 88...264 V AC
s Power supply cable 230 V AC (EU 3x0.75 mm
2
, l = 2.0 m)
d Power supply cable 125 V AC (US 3x18 AWG, l =2.0 m)
g Pneumatic coupling
h Cable to power the component trolley
8 External power supply for SIPLACE HF-Series / D3 component trolley SIPLACE HF-series / D3
06/2006 Edition
16
1.1 Safety instructions
DANGER
Make sure that no one is working on the connected component trolley when you switch on the
power supply.
The external power supply may only be connected to the component trolley if it has been fully dok-
ked out of the placement machine and all electrical connections to the placement machine have
been disconnected.
The device must only be used for its intended purpose, the supply of the component trolley of
SIPLACE HF-series!
The device must not be opened and manipulated.
Before opening the device remove the power plug form the power outlet!
1
1.1.1 Definitions
DANGER
as used in this manual means that death, severe injury or considerable damage to equipment
w i l l occur if the danger instructions are not followed. 1
1
1
1
1
SIPLACE HF-series / D3 8 External power supply for SIPLACE HF-Series / D3 component trolley
06/2006 Edition
17
1.2 Overview
The external power supply is used to power a SIPLACE HF-series component trolley indepen-
dently of the placement machine. 1
The unit is suitable for mains voltages ranging from 88 to 264 V AC. 1
1
Fig. 2 External power supply for component trolley HF03009868-02 (basic unit)
2
Fig. 3 External power supply for component trolley HF03009868-02 (basic unit)
Multi-function plug for
component trolley
48 V pilot lamp
Location switch
Combination
main power connector
CAN bus connector
Compressed air
connector
Pneumatic unit