SA_HF_intern_0194307-02_eng.pdf - 第49页

SIPL ACE HF-Ser ies Replacing the X -axis Read Head [ 03 006472] Serv ice Gan tri es 3 Copy ri ght © 200 4 S ie m ens 0019 43 07- 02 Is su e 1 1/ 2004 3-35 5 1 3 2 1. Visi on board 2. Head interf ace ( under the V ision …

100%1 / 76
3
Service
Gantries
SIPLACE HF-Series
Replacing the X-axis Read Head [03006472]
3-34
00194307-02 Issue 11/2004 Copyright © 2004 Siemens
3.1.5 Replacing the X-axis Read Head [03006472]
1
1. Position of the X-axis read head
SIPLACE HF-Series
Replacing the X-axis Read Head [03006472]
Service
Gantries
3
Copyright © 2004 Siemens 00194307-02 Issue 11/2004 3-35
5
1
3
2
1. Vision board
2. Head interface (under the Vision board)
3. Read head position
Unplug the read head plug-and-socket connection from the
head interface (2).
Plug-and-socket connections
Assembly Gantry Board Terminal
X-axis read head Gantry 1 (DLM head) Head interface 03000901 X15ac
X-axis read head Gantry 2 (Twin head) Head interface 03000901 X15bc
3
Service
Gantries
SIPLACE HF-Series
Replacing the X-axis Read Head [03006472]
3-36
00194307-02 Issue 11/2004 Copyright © 2004 Siemens
Disassembly
4
3
1
2
1. Head mount - front view
2. Read head
3. Fastening screws
4. Grub screws for fastening
CAUTION
Do not loosen or unscrew the grub screw (4).
Unthread the connection cable as far as the read head (2).
Undo the three screws (3) fastening the X-axis read head (2)
and carefully lift off the read head.