3 Serv ice Cu tter SIPL ACE HF-Ser ies Replacing the Cu tter Blades [03009259 - xx] 3-50 0019 43 07- 02 Is su e 1 1/ 2004 Copy ri gh t © 2 004 S ie m ens 1 2 4 1 5 4 3 2 Lubricate the contact/slide su rfac es for the m…

SIPLACE HF-Series
Replacing the Cutter Blades [03009259-xx]
Service
Cutter
3
Copyright © 2004 Siemens 00194307-02 Issue 11/2004 3-49
Installation
2
3
4
1
4
3
2
Correctly insert the moveable blade (1) into the cutter and shift
it along to its original installation position.
Apply Loctite no. 243 to the two M4 screws, to fasten the joint in
the moveable blade.
Insert the screws (2) into the left and right holes provided in the
moveable blade.
NOTE:
Make sure that the joint (3) can slide into the slot (= anti-twist
function) in the moveable blade without obstruction.
Use an SW 10 open-ended wrench to push against the relevant
joint(3) and then tighten both screws (2) to a torque of 2. – 3. N.
Replace the two covers (caps).
Place the two new spacers (4) to the left and right of the
moveable blade. The spacer side marked with a number must
face towards the blade.
The spacers and blades are matched !

3
Service
Cutter
SIPLACE HF-Series
Replacing the Cutter Blades [03009259-xx]
3-50
00194307-02 Issue 11/2004 Copyright © 2004 Siemens
1
2
4
1
5
4
3
2
Lubricate the contact/slide surfaces for the moveable blade, as
described in the section „Preparation“.
CAUTION
Do not lubricate the blades themselves.
Place a shim (0.5 - 1.0 mm thickness) on the left and right,
between the spacer and the front of the blade (1).
Place the previously removed holding-down device (2) onto the
new spacers.
The holding-down devices with function status 03 are
designed for use with cutters of function status -04 (= with
tape deflector).
Reinsert the tape deflector unit (3) and screw in the 4 hexagon
socket-head screws (4) by hand.
Push the spacers (with inserted shim)as far as possible in the
direction of the moveable blade. The maximum permissible gap
is 1.0 mm.
In this position, tighten the 4 screws (4) on the tape deflector
holder crosswise (tightening torque).
Remove the two shims.
Insert the new stationary blade (5) in the correct position and
screw tighten.

SIPLACE HF-Series
Replacing the Cutter Blades [03009259-xx]
Service
Cutter
3
Copyright © 2004 Siemens 00194307-02 Issue 11/2004 3-51
Final Work
1
2
Use a feeler gauge to check the gap between the tape deflector
(1) and the moveable blade (2), along the entire length and
width of the blade.
The 0.05 mm feeler gauge should fit through the gap.
The 0.25 mm feeler gauge should not fit through the gap.
If the gap is not correct, check:
Whether the wrong holding-down device has been installed
(with function status < 03)
The holding-down devices are those designed for cutters
with function status -04 (= with tape deflector)
Whether the blades, tape deflector etc. were cleaned
before installation
If the gap is correct:
Replace the protective sheet, deflector plate and cover plate.
Make sure that the edges are parallel.
CAUTION
Make sure that the cables and hoses are not trapped or subjected to
excess strain.
Remove the clamps form the cutter/ remove the cutter from the
assembly plate.
Install the cutter.