7.6.4 Searching for component shapes
To search the SIPLACE Pro database for component shapes that match the current measure-
ment, choose "Object Find component shape..." from the menu.
The search returns a list of all the component shapes that can be used to successfully perform the
current measurement.
7.6.5 SIPLACE Vision Teach Station view "Test suites"
The SIPLACE Vision Teach Station has a new view: "Test suites".
A test suite comprises:
– a set of measurement context files,
– Vision data, i.e. geometry data of the measurement object and illumination and algorithm
parameters,
– a test suite file (*.svts) used to store all the information for a test suite.
7.6.5.1 Test run with a test suite
When a test run is performed with a test suite, measurements are carried out with every
measurement context of the test suite. Only the images and the illumination settings from the mea-
surement context are used for these measurements. All the other Vision data used is taken from
the test suite.
This allows the Vision data from a test suite to be optimized across multiple measurements.

Vision Teach Station User Manual 7 Software
05/2016 Edition 7.6 Features as of the 4.3.1 VTS version
157
7.6.5.2 Results from a test suite
The results are displayed after every test run.
"Result": Current result ("Successful", "Failed" or "Deviation")
"Previous measurement result": Result of the test suite run using the Vision data prior to the last
change ("Successful", "Failed" or "Deviation").
"Expected result": Here the user can specify the expected result of the measurement ("Success-
ful", "Failed" or "Specified position"). This is intended to assist users in determining the objectives
that they wish to achieve by manipulating the test suite Vision data.
Creating a test suite
A test suite can be created in the "Measurement contexts" and "Test data" views.
A new test suite can be created by clicking "New test suite" in the "Test suites" view.
Editing a test suite
A test suite file can be renamed or deleted when it is selected in the folder hierarchy view.
Measurement contexts of a test suite can be deleted, copied or added.
Editing the Vision data of a test suite
It is possible to select the Vision data of a test suite from a SIPLACE Pro component shape, a
measurement context file or a Vision data XML file.
The "Reset Vision data" button deletes the Vision data from the test suite.
It is not possible to perform a test run if a test suite does not possess any Vision data.
The Vision data of a test suite can be edited by opening a measurement context of the test suite
in the SIPLACE Vision views.
7.6.6 Software licensing
See section 7.4, page 152. 7
7.6.7 Display of station measurement contexts
See section 10.2.5, page 172. 7
7.6.8 Illumination calibration
The camera illumination calibration is available as of theVTS 5.1.1 version. The description of the
illumination calibration can be found in the following document: "Camera Calibration FCCS digital
/ Kamerakalibrierung FCCS digital", item no.: [00196449-03]. 7

8 Starting the vision teach station Vision Teach Station User Manual
8.1 Switching on the vision teach station 05/2016 Edition
158
8 Starting the vision teach station
Check the power cable connections before you switch on the vision teach station.
– Base module and PC see section 4, from page 115.
– Cameras see section 5, from page 118.
WARNING 8
NEVER remove the 26-pin ribbon cable from the Collect&Place head camera while the base
module is switched on as this could damage the LED driver board for the camera.
8.1 Switching on the vision teach station
Switch the base module on at the power switch.
The three LEDs on the back of the base module light up.
Switch the PC on.
Log in as Administrator (see section 7.2, page 142) or as a user.
8.2 Starting the vision teach station application
Double-click on the "Teach Station" icon to start the application. The application will detect any
cameras that are connected. The live image of the first camera is displayed on the application's
starting screen. If there are two cameras connected, you can toggle between the two.