6-42 AKHEDT -ID 0609-002 2.1.20 Nozzle Stocker Offset When the "Noz. Stocker" tab is pressed in the "Device Offset" tab sheet and the "1-1/1-2" tab is selected, the following tab sheet appea…

100%1 / 341
6-41
AKHEDT-ID
[1] X (Horizontal) and Y (Vertical) [mm]
This offset data is used to adjust the positional deviations compared
with the design dimensions of the nozzle stocker unit positions (viewed
from the PCB positioning X/Y coordinates (Machine Reference X/Y
Coordinates: Origin P0)). The value base on the machine reference XL
coordinate system must be entered in each text box.
[2] L (Height) [mm]
When a value is entered with a plus (+) sign, the nozzle change
position (height) is changed in the L (+) direction, concluding that the
descending stroke has increased.
L(+)
Nozzle
Nozzle Mounting Level
(Upper Surface of Nozzle Stocker Block)
Fig. 3F32
0602-001
2.1 Device Offset Data
6-42
AKHEDT-ID
0609-002
2.1.20 Nozzle Stocker Offset
When the "Noz. Stocker" tab is pressed in the "Device Offset" tab sheet and
the "1-1/1-2" tab is selected, the following tab sheet appears.
Note
As for the "2-1/2-2" tab sheet, the same contents as the "1-1/1-2" tab sheet
are displayed.
[1] [2]
Fig. 3F33 Nozzle Stocker "1-1/1-2" Tab Sheet
2.1 Device Offset Data
6-43
AKHEDT-ID
[1] X (Horizontal) and Y (Vertical) [mm]
This offset data is used to adjust the positional deviations based on the
design dimensions of the nozzle stocker unit positions (viewed from the
PCB positioning reference X/Y coordinates (Machine Reference X/Y
Coordinates: Origin P0)). The value based on the machine reference
X/L coordinate system must be entered in each text box.
When values are entered with a plus (+) sign, the nozzle change
positions are changed to "X (+)" and "Y (+)" shown below.
1-4
1-3
1-2
1-1
2-1
2-2
2-3
2-4
4
3
2
1
1
2
3
4
5
6
7
8
9
10
11
12
Placement Reference
X/Y Coordinate System
Y(+)
X(+)
2
(Front Side of Machine)
(Rear Side of Machine)
Nozzle Stocker A
1
Fig. 3F34
[2] L (Height) [mm]
When an offset value is set with a plus (+) sign, the nozzle change
position (height) is changed to "L (+)" shown below, concluding that
the descending stroke has increased.
L(+)
Nozzle
Nozzle Mounting Level
(Upper Surface of
Nozzle Stocker Block)
Fig. 3F35
Note
As for L, only the master becomes effective.
0602-001