6-63 AKHEDT -ID [6] Furnace Signal Check Set "Disable" or Enable" to determine whether or not the furnace signal check function should be activated. Note When "SMEMA" is set in the "Input mo…

100%1 / 341
6-62
AKHEDT-ID
[3] Auto stop mode
"Enable" or "Disable" can be set in this text box to determine whether
or not the automatic stop function should be used.
"Enable" in "Auto stop mode" Text Box (Standard Setting)
The machine stops when the automatic operation is started by pressing
the [START] button with the machine in the initialized mode (no PCB
on the machine, the machine is waiting for a PCB to be sent from the
input machine and detects that "RUN" signal has stopped coming
from the input machine, and the machine is kept in the condition for 2
seconds.
This function is based on the concept that it will be necessary to
continue automatic operation of the machine when there is no PCB on
the machine and the input machine is not running automatically because
it is apparent that no PCB can be transferred to the machine anymore.
The machine stops automatically when a PCB on the machine is
processed without unprocessed PCB left on the machine and the input
machine is stopped after the last processed PCB on the machine has
been transferred to the output machine.
Note
(a) When the machine is connected to another machine manufactured by
another company, this function may not be activated.
(b) When "SMEMA" is set in the "Input mode" text box of the label
"Input Setup" or in the "Output mode" text box of the label "Output
Setup", this function cannot be used.
[4] Simultaneous transfer setup
Set "Enable" or "Disable" to determine whether or not the PCB transfer
should be made simultaneously between the input and positioning
conveyors and between the positioning and output conveyors.
Enable :
The simultaneous transfer setup function is
used.
Disable (Independent) :
The simultaneous transfer setup function is
not used.
Disable (Asynchronous) :
When a PCB to be discharged passes
through the input sensor on the output
conveyor, the machine starts to take in the
subsequent PCB.
[5] Output conveyor PCB Out
Set "Disable" or "Enable" to determine whether or not a disengaged
PCB should be detected in the output conveyor section.
2.2 Auto Operation
0609-003
6-63
AKHEDT-ID
[6] Furnace Signal Check
Set "Disable" or Enable" to determine whether or not the furnace signal
check function should be activated.
Note
When "SMEMA" is set in the "Input mode" text box of the label "Input
Setup" or in the "Output mode" text box of the label "Output Setup", this
function cannot be used.
[7] Input Setup
Input mode
Select a parameter according to the PCB unloading system of the input
machine.
Conveyor
The input machine is activated to receive a PCB from the input
machine when the PCB transfer signal is received from the input
machine.
Pusher
The pusher of the input machine forces a PCB out to the input
conveyor of the machine.
When the PCB detection sensor (for the pusher) is not provided at
the inlet side of the input conveyor, do not set "Pusher" in the text
box.
SMEMA
PCBs are transferred according to the "SMEMA" standard.
Pusher delay timer [sec]
When "Pusher" is set in the "Input mode" text box of the label "Input
Setup", it is required to specify the delay (waiting) time for the loading
action to start after the inlet sensor has detected a PCB.
PCB delivery Position
Set the position where PCBs are received.
Transfer speed
Set the PCB transfer speed.
Default:
300 [mm/sec]
2.2 Auto Operation
0609-003
6-64
AKHEDT-ID
[8] Output Setup
Output mode
Select parameter to determine how to transfer PCBs from the main
machine to the output machine.
Standard
When the output machine is manufactured by us, set "Standard" in
the text box.
When the work request signal is received from the output machine,
the PCB transfer signal of the machine is turned ON and a PCB is
transferred to the output machine by the output conveyor.
When the work request signal is not turned OFF within the speci ed
time after a PCB unloading action has started, the machine stops in
an error condition.
Interval
When the work request signal of the output machine is turned ON,
PCBs on the machine side are transferred to the output machine.
The conveyor stops when the output conveyor timer 1 has reached
the speci ed time.
The machine starts its unloading actions when the unloading
condition is ful lled after the conveyor has stopped running and
the time speci ed in the "Output interval timer [sec]" text box has
elapsed.
Note
No error detection is made.
SMEMA
PCBs are transferred according to the "SMEMA" standard.
Output interval timer [sec]
When "Interval" is set in the "Output mode" text box, set the time as
interval time for PCB unloading actions.
PCB delivery Position [mm]
Set the position where PCBs are received.
Transfer speed [mm/sec]
Set the PCB transfer speed.
Default:
300 [mm/sec]
Note
When the unloading system of the output machine is used in a
mode other than the standard one and the PCB transfer speed of
the output machine is slow, the transfer speed must be adjusted
to one on the output machine side.
A PCB may be trapped during the arrangement of the conveyor
Y position.
2.2 Auto Operation