Table of Contents 8 Software Version Description SIPLACE Setup Center 2.3
Table of Contents
Software Version Description SIPLACE Setup Center 2.3
7
7.1.5 Traceability............................................................................................................................................ 69
7.1.6 Abrüsten................................................................................................................................................ 69
7.1.7 Barcode-Etiketten ................................................................................................................................. 69
7.1.8 Rüstliste ................................................................................................................................................ 69
7.1.9 Spleißüberwachung .............................................................................................................................. 69
7.1.10 Recovery Placement............................................................................................................................. 70
7.2 Bekannte Sachverhalte / Probleme (Allgemein) .............................................................................. 70
7.2.1 Rüstverifikation ..................................................................................................................................... 70
7.2.2 Mengenverwaltung................................................................................................................................ 70
7.2.3 Förderer ................................................................................................................................................ 70
7.2.4 Linienrechner ........................................................................................................................................ 70
7.2.5 SIPLACE Pro ........................................................................................................................................ 71
7.2.6 Länge der Rüstungsnamen................................................................................................................... 71
7.2.7 SMV ...................................................................................................................................................... 71
7.2.8 Docking Station..................................................................................................................................... 71
7.2.9 Manuelle Barcode-Eingabe................................................................................................................... 72
7.2.10 Mehrere Instanzen von Setup Center ................................................................................................... 72
7.2.11 Barcode Scanner .................................................................................................................................. 72
7.2.12 Betriebsmittelverwaltung....................................................................................................................... 72
7.2.13 Lieferanten-Barcode ............................................................................................................................. 72
7.2.14 Barcode-Fragment................................................................................................................................ 73
7.2.15 Setup Center beenden.......................................................................................................................... 73
8 Abkürzungen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
9 Anhang A: Informationen zum SIPLACE Setup Center Error Reporting Tool . . . . 77
10 Anhang B: Unterstützte Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Table of Contents
8 Software Version Description SIPLACE Setup Center 2.3

Brief Description
Software Version Description SIPLACE Setup Center 2.3
9
1Brief Description
SIPLACE Setup Center is an application for performing setup verification on SIPLACE machines (online)
and in the pre-setup area (offline).
Setup verification is the term used for step-by-step checking of the assignment of a component from the
target setup to a track in the actual setup. SIPLACE Setup Center obtains the data on the target setup
through the SIPLACE Pro Interface (SPI). The component is identified by barcode labels on the
packaging unit, which SIPLACE Setup Center reads by means of a scanner system and processes via
a flexible barcode label definition. The track is assigned to the component by way of the track barcode
on the machine or the component verification button on the X-feeder. All the data captured during a setup
verification is saved by the SIPLACE Setup Center in its own database.
SIPLACE Setup Center can currently handle packaging units that are uniquely identifiable and
packaging units that are assigned to a batch. The groups are differentiated by the fact that a packaging
unit has a unique barcode (UID) or a batch identification (ICL), such as a serial number. For technical
reasons, Setup Center cannot provide all functions with the same degree of user-friendlieness in ICL
mode, so we recommend equipping packaging units with a unique identification.
SIPLACE Setup Center currently supports online setup verification for all SIPLACE component
placement machines (except for F3 and S15). Furthermore, SIPLACE Setup Center differentates
between forced and unforced setup verification. Unforced setup verification is carried out without a
connection to the station. This means there is no compulsion to perform setup verification and the
production process can take place without it. Forced setup verification is carried out with a connection
to the station and requires successful setup verification before production. This is implemented as
follows: once an order or a packaging unit changeover has been downloaded, the machine deactivates
all divisions in which there are packaging units for which no setup verification data has been received.
This means the line operator needs to successfully verify all the necessary components/packaging units
for the product before production can begin. Forced online setup verification is not supported by C-
Series machines.
SIPLACE Setup Center also allows offline setup verification to be carried out in the pre-setup area.
Offline setup verification is performed for a changeover table of a selected setup. Following completion
of setup via offline verification, the changeover table can be moved from the pre-setup area to the
production line and reported to the station via the "changeover table management". All SIPLACE
machines are supported here.
The concept of device recognition for machines (Unique Machine ID), changeover tables (Unique Table
ID) and feeders (Unique Feeder ID) was introduced with the support of X-Series machines. The
equipment of the X-Series supports the concept directly by way of the hardware. For the F-, S-, HF-, HS-
and C-Series the identification needs to be printed by means of Setup Center and attached manually.
In contrast to previous setup verification systems, the SIPLACE Setup Center uses a radio scanner
system, which displays the current setup data for the user. The radio scanner system offers easy-to-
follow user prompts. The four-line display gives the user information and is also used to control certain
processes. The menu structures are modeled on those used for the operation of mobile phones. In
addition, the scanner indicates the successful or unsuccessful completion of actions by various audible
and visual signals.
ATTENTION:
The line ID used in Setup Center 2.0 and 2.1 is no longer supported and is replaced by the
machine ID. For this reason it is necessary to remove all existing barcode labels for online setup
verification, for example ‚Table Verification’, ,Refill’, ‚Shift Change’, ‚Component Search’ etc.
and to overwrite these with new labels.