Setup Center mit Setup Center Interface.pdf - 第18页
3 Application progra m interface (API) description SIPLACE Ausgabe 05/2007 18 3.1.3.2 Enumeration JedecLevel The IPC/JEDEC Moisture Sensitive Device Levels shall ensure, that component s are assembled within specified fl…

SIPLACE 3 Application program interface (API) description
Ausgabe 05/2007
17
3.1.3 Enumeration ValidationStatus
Validation state of a division 3
3
3.1.3.1 Enumeration TableType
Table types valid for SIPLACE machines 3
3
3
3
3
3
3
3
3
3
Member name Description
None
ValidationStatus: None
Ignore
ValidationStatus: Ignore
Ok
ValidationStatus: Ok
Unchecked
ValidationStatus: Unchecked
Warning
ValidationStatus: Warning
Fail
ValidationStatus: Fail
Member name Description
None
None
ChangeOver120
ChangeOver120
ChangeOver120_0201
ChangeOver120_0201
ChangeOver120_F
ChangeOver120_F
ChangeOver72
ChangeOver72
ChangeOver90
ChangeOver90
ChangeOver90D
ChangeOver90D
Wpc90D
Wpc90D
Mtc1
Mtc1
Mtc2
Mtc2
Wpc120
Wpc120
X
X table

3 Application program interface (API) description SIPLACE
Ausgabe 05/2007
18
3.1.3.2 Enumeration JedecLevel
The IPC/JEDEC Moisture Sensitive Device Levels shall ensure, that components are assembled
within specified floor life 3
3.1.3.3 Enumeration FeederType
Restrictions 3
FeederType values are defined by machine. Possible customer extensions (range > 1000000) are
not supported by this interface (Setup Center). 3
Values 3
Member name Description
L_1
Level 1: Unlimited - The component can be assembled unlimited (max. 30°C
/ 85% RH)
L_2
Level 2: 1 year - The component can be assembled 1 year after the opening
date of the pakkaging unit at (max. 30°C / 85% RH)
L_2A
Level 2A: 4 weeks - The component can be assembled 4 weeks after the
opening date of the packaging unit at (max. 30°C / 85% RH)
L_3
Level 3: 168 hours - The component can be assembled 168 hours after the
opening date of the packaging unit at (max. 30°C / 85% RH)
L_4
Level 4: 72 hours - The component can be assembled 72 hours after the
opening date of the packaging unit at (max. 30°C / 85% RH)
L_5
Level 5: 48 hours - The component can be assembled 48 hours after the
opening date of the packaging unit at (max. 30°C / 85% RH)
L_5A
Level 5A: 24 hours - The component can be assembled 24 hours after the
opening date of the packaging unit at (max. 30°C / 85% RH)
L_6
Level 6: 6 hours - The component can be assembled 6 hours after the
opening date of that packaging unit at (max. 30°C / 85% RH)
Member name Description
Unknown
FeederType is not known
Linear45
Value: 1
Linear95
Value: 2
Linear10
Value: 3
Linear15
Value: 4
Linear30
Value: 5
BulkCase_0402_0603
Value: 6
TwoFeedElectric
Value: 7
Tape8mmElectric
Value: 8
TwoFeedMechanical
Value: 9
OneFeedMechanical
Value: 10
Tape12mm
Value: 11
Tape16mm
Value: 12

SIPLACE 3 Application program interface (API) description
Ausgabe 05/2007
19
Tape24mm
Value: 14
Tape32mmPaper
Value: 15
Tape32mmBlister
Value: 16
Tape44mm
Value: 17
Tape56mm
Value: 18
Tape4mmWithFlap
Value: 19
Tape2mmWithFlap
Value: 29
RejectConveyor_SIPLACE
Value: 49
Tape16mmIII
Value: 55
Tape24mmIII
Value: 56
Tape32mmIII
Value: 57
Tape44mmIII
Value: 58
Tape56mmIII
Value: 59
Tape12mmS
Value: 60
Tape16mmS
Value: 61
Tape24mmS
Value: 62
Tape32mmS
Value: 63
Tape44mmS
Value: 64
Tape56mmS
Value: 65
Tape72mmS
Value: 66
Tape88mmS
Value: 67
Tape3x8mmS_0201
Value: 78
Tape3x8mmS
Value: 79
Tape8mmST
Value: 80
Tape12mmST
Value: 81
Tape16mmST
Value: 82
Tape24mmST
Value: 83
Tape2x8mmTypeC
Value: 100
Tape12mmTypeC
Value: 101
Tape16mmTypeC
Value: 102
Tape24mmTypeC
Value: 103
Tape32mmTypeC
Value: 104
Tape3x8mmTypeC
Value: 105
Tape8mmFeed
Value: 149
Tape8mmS
Value: 150
FimeCore
Value: 151
BulkCaseAir
Value: 153
Tape8mmX
Value: 264
Tape12mmX
Value: 268
Tape16mmX
Value: 272