9 WF2 CA4 V2 Clean / replace the cooling air filter 2 min 2 / 2 C A U T I O N !  R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n a n c e Machine St…

100%1 / 50
9 WF2 CA4 V2 Clean / replace the cooling air filter 2 min 1 / 2
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Transport Empty
NOTICE! ESD guidelines are to be followed Tool: Wear Part:
W26
Consumables:
C19
www.asm-smt.com
1 The air filter is positioned at the side of
location 3.
2 Open the door (1), unscrew the wing nut
(2) and remove the filter (3).
3 Blast the dirt out.
4 Check if it is clean. 5 If OK go to Step 7. 6 If not OK replace it with a new one.
9 WF2 CA4 V2 Clean / replace the cooling air filter 2 min 2 / 2
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Transport Empty
NOTICE! ESD guidelines are to be followed Tool: Wear Part:
W26
Consumables:
C19
www.asm-smt.com
7 Place the filter (1), fix it with the wing nut
(2) and close the door (3).
10 WF2 CA4 V2 Clean the stationary camera (CPP M) 2 min 1 / 1
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Transport Empty
NOTICE! ESD guidelines are to be followed Tool: Wear Part: Consumables:
C2
www.asm-smt.com
1 Move all gantries to the end limit. 2 Take out the upper section of the station-
ary camera.
3 Clean the slanted glass.
4 Refit the upper section of the stationary
camera.