13 WF2 CA4 V2 Calibrate the C&P20 A/P/M2 head 14 min 4 / 4 C A U T I O N ! R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n a n c e Machine Sta…

13 WF2 CA4 V2 Calibrate the C&P20 A/P/M2 head 14 min 3 / 4
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Transport Empty
NOTICE! ESD guidelines are to be followed Tool:
T2, T4 or T100
Wear Part: Consumables:
www.asm-smt.com
13 Select the head to be calibrated. 14 Select the head calibration type (standard
or brief).
15 Click on "Next".
16 Click on "Start". 17 Press the machine start button. 18 Click on "Finish".

13 WF2 CA4 V2 Calibrate the C&P20 A/P/M2 head 14 min 4 / 4
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Transport Empty
NOTICE! ESD guidelines are to be followed Tool:
T2, T4 or T100
Wear Part: Consumables:
www.asm-smt.com
19 Press the machine stop button. 20 Open the cover. 21 Remove the reject bin.
22 Remove the nozzles from the reject bin. 23 Return the reject bin. 24 Close the cover.

14 WF2 CA4 V2 Check the filter discs of C&P20 A/P/M2 2 min 1 / 1
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Transport Empty
NOTICE! ESD guidelines are to be followed Tool: Wear Part: Consumables:
www.asm-smt.com
1 Click on the "Maintenance" icon. 2 Select all heads. 3 Click on the "Check filter disk" icon.
4 Press the machine start button. 5 Check if the result is OK (green hook). 6 If the result is NOT OK (red cross) contact
service.