TM3070.Immediate stop after one pick.pdf - 第10页
SMT Software Engineering Group IMOperation sYAMAHAMOT ORCO.,LTD. MDOC -SOFT50136 10 /10 Set [V ac uum Check] to “Check ”

SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50136
8/10
3.5.6 Parts log
When [Ea7992: Parts Pick Up Error] occurs,
Consumption is NOT counted because feeding
is controlled in this case.
Also, PickUp Error Counter is not counted. (because this counter shows error counter of
consumed parts)
When the machine is reset after Ea7992 occurs, parts are dumped (consumed) and PickUP
Error and Consumption are counted.
3.5.7 Board log
When [Ea7992: Parts Pick Up Error] occurs,
Pick Error Counter is NOT counted because
feeding is controlled not to consume the parts in this case.
When the machine is reset, parts are dumped (consumed) and PickUP Error is counted.

SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50136
9/10
4. Setting
To activate this function, you need to set as below.
Set
[Basic] -
[Package] to
“Tape”
Set
[Basic] -
[Retry times] –
“No Retry (by
1pick)”
Set
[Pick&MountVa
cuum Check]
to
“SPECIAL
CHK” or
“Norma CHK”
Tape

SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50136
10/10
Set
[Vacuum
Check]
to
“Check”