00191209-01.pdf - 第14页

Arbeitspl an Nachrüstung Software 404.x x an SIPLACE Anlagen Workflow retrof it software versi on 404.xx at SIPLACE machines 14 of 16 1.Station 12 1,13t Retrofit PC stand + Change station computer / 13 4h WIN NT installa…

100%1 / 16
Arbeitsplan Nachrüstung Software 404.xx an SIPLACE Anlagen
Workflow retrofit software version 404.xx at SIPLACE machines
13 of 16
4 Workflow
Retrofit Software 404.xx
1 5,13t
Linecomputer
2 0,75t
Save masterdata at LC
3 0,5h
ChangeLC/ RetrofitCD
ROMdrive
4 0,5h
UNIX5.0 installationat LC
5 3h
Save MA-Data at
1.Station
6 0,5h
Changeaxis epromat
1.Station
7 1h
Changevision epromat
1.Station
8 1h
Changehead epromat
1.Station
9 0,5h
Restore master data at LC
10 0,5h
LCsoftware installation
11 1,5h
These jobs has to be performed
during the UNIX installation
(during data extract from CD-
ROM)
Arbeitsplan Nachrüstung Software 404.xx an SIPLACE Anlagen
Workflow retrofit software version 404.xx at SIPLACE machines
14 of 16
1.Station
12 1,13t
Retrofit PCstand +
Changestation computer/
13 4h
WINNTinstallationat
Station
14 3h
Save MA-Dataat
2.Station
15 0,5h
Changeaxis epromat
2.Station
16 1h
Changehead epromat
2.Station
18 0,5h
SR/MC/SITESTinstallation
at Station
19 2h
Changevision epromat
2.Station
17 1h
Arbeitsplan Nachrüstung Software 404.xx an SIPLACE Anlagen
Workflow retrofit software version 404.xx at SIPLACE machines
15 of 16
WINNTinstallationat
Station
22 3h
Save MA-Dataat
2.Station
23 0,5h
Changeaxis epromat
2.Station
24 1h
Changehead epromat
2.Station
26 0,5h
SR/MC/SITESTinstallation
at Station
27 2h
Retrofit PCstand +
Changestation computer/
21 4h
Changevision epromat
2.Station
25 1h
2.Station
20 1,13t