TM3891.Immediate stop after one pick.pdf - 第10页

    SMT Software Engineering Group  IMOperation sYAMAHAMOT ORCO.,LTD.  MDOC -SOFT50136  10 /11  4. Setting T o activate th is f unction, yo u need to set as below . Set [Basic] - [Package] to “T ape” Se…

100%1 / 11
SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50136
9/11
3.5.7 Feeder log
When Ea7992 occurs, “Feeder Counter” an (Rev.1 delete) “Pick Error Counter” is NOT
counted on the feeder log because SS-feeder is not fed.
(Rev.01 add) When Ea7994 occurs, “Feeder Counter” and Pick Error Counter” are NOT
counted on the feeder log because the error message instructs operator to rewind the feeder by
manual.
(Rev.01 add) When Ea7995 occurs, “Feeder Counter” and “Pick Error Counter” are counted
because SS-feeder / air feeder is fed.
3.5.8 Parts log
When Ea7992 or Ea7994(Rev.1 add) occurs, “Consumption” is NOT counted because the
feeder is not fed.
(Rev.01 add) Since “Consumption” is not counted, “No Parts Error ounter” is NOT counted as
it is considered that parts exist.
Also,
“Pick Error Counter” is NOT counted. (This pick error counter means error count for
parts consumption)
(Rev.01 add) When Ea7995 occurs, “Consumption”, “No Parts Error Counter”, and “Pick Error
Counter” are counted because feeder is fed.
SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50136
10/11
4. Setting
To activate this function, you need to set as below.
Set
[Basic] -
[Package] to
“Tape”
Set
[Basic] -
[Retry times] -
“NO RETRY
(By 1Pick)”
Set [Vacuum
Check] to
“Check
SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50136
11/11
Set [Pick&Mount
Vacuum Check]
to “SPECIAL
CHK” or
“NORMAL
CHK”.
(Rev.01 add)
To dump the
parts after
“Ea7995: part
pick up error”,
set [Machine] –
[Mechanical] –
[Position] –
[Dump After
1Pickup Error] to
“Use”.