TM3832.Shifted check of board fixing.pdf - 第10页

 S M T S o f t w a r e E n g i n e e r i n g G r o u p I M O p e r a t i o n s Y A M A H A M O T O R C O . , L T D . MDOC-SOFT501 81 10/10 Please set up [Max Diff XY(mm)] or [Max Diff R(deg)] in the range of 0.0 01 from…

100%1 / 10
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50181
8/10
Name Explanation
Setting value XY “The value of [Machine]-[Setting]-[Machine Data]
-[Mechanical]-[Position]-[Table A]-[Mount After FID Check]-[Max
Diff XY(mm)]” is displayed.
Setting value R “The value of [Machine]-[Setting]-[Machine Data]
-[Mechanical]-[Position]-[Table A]-[Mount After FID Check]-[Max
Diff R(deg)]” is displayed.
4 3 Log
When Ea7996:PCB fiducial mark shift error is occurred, the following error numbers and
the contents of an error are displayed on an error log.
Following contents are displayed in the “Details” column.
Name Contents
Lane Lane number which error occurred.Only dual lane machine
Table Mount table number which error occurred.
MaxXY= “Max Diff XY(mm)]” displayed in error message.
MaxR= “Max Diff R(deg)] “ displayed in error message.
DifX= “Difference of the direction of X” displayed in error message.
DifY= “Difference of the direction of Y” displayed in error message.
DifR= “Difference of the direction of R” displayed in error message.
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50181
9/10
5 Settings
The setting method to use this function is as follows.
[Board]-[Fiducial]
Set [Board] to
[Execute].
▼ [Machine]-[Setting]-[Machine Data] -[Mechanical]-[Position]-
[Table A]-[Mount After FID Check]
Set [Board FID
Check] to [Enable].
(Initial value:[Disable])
Choose from the
following inside in
[Diff Check Timing].
AllBoard
SwitchBoard
AutoRun
(
Initiall value:[AllBoard])
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50181
10/10
Please set up
[Max
Diff XY(mm)] or [Max
Diff R(deg)]
in the
range of 0.001
from
1.000.
(Initial value:[0.000])