TM3832.Shifted check of board fixing.pdf - 第7页

 S M T S o f t w a r e E n g i n e e r i n g G r o u p I M O p e r a t i o n s Y A M A H A M O T O R C O . , L T D . MDOC-SOFT501 81 7/10 [ Detail ] 4 2.2 Dat a Check Error W hen a board data is read or auto-r u n is st…

100%1 / 10
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50181
6/10
4.2 ErrorMessage
4 2.1 PCB fiducial mark shift error
If a difference check error occurs, the following error messages will be displayed.
[ Outline ]
Name Explanation
Setting
value XY
“The value of [Machine]-[Setting]-[Machine Data]
-[Mechanical]-[Position]-[Table A]-[Mount After FID Check]-[Max Diff
XY(mm)] is displayed.
Setting
value R
“The value of [Machine]-[Setting]-[Machine Data]
-[Mechanical]-[Position]-[Table A]-[Mount After FID Check]-[Max Diff
R(deg)]” is displayed.
X Absolute value( the PCB fiducial correction value X before mounting -
the PCB fiducial correction value X after mounting)
Y Absolute value( the PCB fiducial correction value Y before mounting -
the PCB fiducial correction value Y after mounting)
R Absolute value( the PCB fiducial correction value R before mounting -
the PCB fiducial correction value R after mounting)
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50181
7/10
[ Detail ]
4 2.2 Data Check Error
When a board data is read or auto-run is started in the maximum difference XY or the
maximum difference R is a value of "0.000", the following error messages will be displayed.
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50181
8/10
Name Explanation
Setting value XY “The value of [Machine]-[Setting]-[Machine Data]
-[Mechanical]-[Position]-[Table A]-[Mount After FID Check]-[Max
Diff XY(mm)]” is displayed.
Setting value R “The value of [Machine]-[Setting]-[Machine Data]
-[Mechanical]-[Position]-[Table A]-[Mount After FID Check]-[Max
Diff R(deg)]” is displayed.
4 3 Log
When Ea7996:PCB fiducial mark shift error is occurred, the following error numbers and
the contents of an error are displayed on an error log.
Following contents are displayed in the “Details” column.
Name Contents
Lane Lane number which error occurred.Only dual lane machine
Table Mount table number which error occurred.
MaxXY= “Max Diff XY(mm)]” displayed in error message.
MaxR= “Max Diff R(deg)] “ displayed in error message.
DifX= “Difference of the direction of X” displayed in error message.
DifY= “Difference of the direction of Y” displayed in error message.
DifR= “Difference of the direction of R” displayed in error message.