00194605-04.pdf - 第23页
Retrofit instructions: PE film for X cable and hose carrier, HF series 01/2006 Edition 23 : Loosen the screws on the X cable and hose car r ier mount on th e gantry arm, and remove the pressure plate. 2 2 : Remove the pr…

Retrofit instructions: PE film for X cable and hose carrier, HF series
01/2006 Edition
22
: Loosen all the screws on the X axis compression spring and remove the spring.
The appearance may differ according to when the placement machine was produced.
2
2
2
2
2
2
2
2
2
Loosen the 6 screws
Loosen the 2 screws

Retrofit instructions: PE film for X cable and hose carrier, HF series
01/2006 Edition
23
: Loosen the screws on the X cable and hose carrier mount on the gantry arm, and remove the
pressure plate.
2
2
: Remove the pressure plate from the placement head too, if there is one (differs according to
the version).
2
Loosen screws

Retrofit instructions: PE film for X cable and hose carrier, HF series
01/2006 Edition
24
: Move the placement head so that the two X cable clamps are roughly one over the other.
2
2
: Replace the inlets in the clamps (if existing) with new ones with other thicknesses:
replace inlet 3 mm with inlet 2 mm,
replace inlet 6 mm with inlet 5 mm.
2
Clamp
Inlet 2 mm
Inlet 5 mm