00194340-01.pdf - 第17页
Retrofit Instructions & User’s Manual / Automatic Vacuum Support Pins (AVSP) Edition 04/2006 2.3 Required materials & tools 1 Complete AVSP Option will need the following items: No. Item Description Qty. Item Num…

Retrofit Instructions & User’s Manual / Automatic Vacuum Support Pins (AVSP)
Edition 04/2006
2 Retrofit instructions
2.1 Overview of retrofit instructions
These retrofit instructions can be sub-categorized into 5 main steps for a full installation as
follows:
(1) Compressed air supply installation
(2) Electrical installation
(3) Teach pendant installation
(4) Air distributor installation
(5) Pin module installation
These should be followed in sequence in order to ensure smooth and shortest possible
installation time.
2.2 Pre-conditions
- Station software 504.02 or above
- Other machine options such as ceramic board centering, fine calibration, long board
option and PCB alignment option cannot be used at the same time on the same
placement areas. However, these options can be used independently from AVSP if used
at seperate placement areas. Only PCB barcode is allowed to be used concurrently.
- If necessary, original magnetic support pin is allowed to be used together with AVSP.
- For the AVSP Pneumatics Service Unit an additional preasure supply hose with a inside
diameter of 13mm or ½“ is necessary.
2-12

Retrofit Instructions & User’s Manual / Automatic Vacuum Support Pins (AVSP)
Edition 04/2006
2.3 Required materials & tools
1 Complete AVSP Option will need the following items:
No. Item Description Qty. Item Number
Single Conveyor
1
1 Retrofit Instruction AVSP SIPLACE HS-60 00194340-FS
2)
2 Ret. Kits AVSP HS-60 (Single) 1 03048394-FS
2)
3 AVSP Single Conveyor Distributor Assy 2 03040851-FS
2)
4 AVSP Control Unit 2 03031316-FS
2)
5 HS60 AVSP Pneumatics Service Unit 1 03039864-FS
2)
6 LT Plate Singl. HS-60 (AVSP) Compl. 2 03046506-FS
2)
7 Ret. Kits (AVSP) HS-60 ET Packaging 1 03048900-FS
2)
Dual Conveyor
1
1 Retrofit Instruction AVSP SIPLACE HS-60 0019434-FS
2)
2 Retrofitting Kit (AVSP) SIPLACE HS-60 1 03032556-FS
2)
3 AVSP Dual Conveyor Distributor Assembly 4 3040773-FS
2)
4 AVSP Control Unit 4 03031316-FS
2)
5 HS60 AVSP Pneumatics Service Unit 1 03039864-FS
2)
6 LT Plate Dual HS-60 (AVSP) Compl. 4 03047412-FS
2)
7 Ret. Kits (AVSP) HS-60 DT Packaging 4 03048901-FS
2)
Tab. Fehler! Formatvorlage nicht definiert.-1
1)
Quantity stated is minimum. User may need more if more than one placement areas using
AVSP.
2)
FS is the current functional status.
Tools and consumables required:
- Set of socket wrenches
- Set of screwdrivers
- Set of spanner wrenches
- Cutter plier
2-13

Retrofit Instructions & User’s Manual / Automatic Vacuum Support Pins (AVSP)
Edition 04/2006
2.4 Mechanical and electrical installation
WARNING
Before start installing or uninstalling any air supply, make sure the main valve for
compressed air input to machine is shut off.
WARNING
Before start installing or uninstalling any electrical components, make sure the main power to
machine is shut off and machine is disconnected from the mains.
2.4.1 Compressed air supply installation
→ Remove all feeder tables from the machine and subsequently remove all top plate of
lifting table by removing 4 countersunk screws on each of the table. This will allow more
space during installation.
NOTE
Standard lifting table top plate is not usable with AVSP. AVSP option plate is required.
2-14