No: SI1205003E-000= ANC control board nozzle sensor adjustment procedure
2/12
1. Check if the sensor detects the nozzle properly
1.1 Operation check of the sensor on the I/O window
1. Display the I/O window.
Click the [Unit] button and select the I/O tab.
Figure 1
2. Select NZL STATION from the Input pull-down menu.
Figure 2
Service Engineer
Service Information
No: SI1205003E-000= ANC control board nozzle sensor adjustment procedure
3/12
3. Select the nozzle number of the nozzle station to be checked.
The nozzle number and the condition of the sensor are displayed at the lower part of the window.
Check if the indication of 0/1 switches properly by taking a nozzle in and out the nozzle station.
Figure 3
Service Engineer
Service Information
No: SI1205003E-000= ANC control board nozzle sensor adjustment procedure
4/12
1.2 Check the threshold of the sensor by the CalibSm
Check the threshold by using the CalibSm adjustment utility.
The adjustment procedure varies depending on whether the nozzle change can be performed
automatically or not.
1.2.1 Start up CalibSm adjustment utility
Click the [Utilities] button to start up the CalibSm adjustment utility.
Note:
Log in as Supervisor. Please contact YAMAHA for the password.
Figure 4