Micron Installation V9 Power Up Sequence.pdf - 第9页
POWER UP SEQUENCE MACHINE POWER UP SEQU ENCE Chapter Issue 8, Jan 16 Installation Manual 5.9 18. If correct contact heig ht is achieved go to S tep 24. 19. Close the front printhead cover . 20. Press the System button. 2…

POWER UP SEQUENCE
MACHINE POWER UP SEQUENCE
5.8 Installation Manual Chapter Issue 8, Jan 16
NOTE
If adjustment of the paste level sensor is required, refer to the Technical
Reference manual - Paste Dispenser System - Adjustments and Settings
section.
10. Select Exit.
11. Select Exit.
12. Select Back.
ProFlow Contact
Position Setup
For machines using ProFlow only, set up the contact height position as follows:
1. Select Open Cover Commands.
2. Select Carriage To Front.
3. Select Back.
4. Open the front printhead cover.
5. Load the calibration screen into the chase.
6. Fit an empty transfer head to the ProFlow pressure mechanism and remove
the ProFlow cover.
7. Position a 0.1mm shim on the stencil under the transfer head.
8. Close the front printhead cover.
9. Press the System button.
10. Select Load Screen.
11. Select Maintenance.
12. Select Calibrations.
13. Select ProFlow.
14. Select ProFlow Heights.
The following window is displayed:
The ProFlow contact position sets the height of the ProFlow printhead so
that it just touches the stencil surface.
15. Using the Incr. or Decr. buttons, set the ProFlow contact position to 5.5mm.
16. Select Move to Position, the ProFlow unit is driven to the position set.
17. Open the front printhead cover.
NOTE
Correct contact height is when the shim is just held between the transfer
head wipers and stencil. At this position it is not possible to slide the shim
sideways past the transfer head skis.
Minimum Maximum Increment Default
- 10mm +10mm 0.1mm 0.0mm
ProFlow Calibrations
PFLOW CONTACT POS.
0.0
mm

POWER UP SEQUENCE
MACHINE POWER UP SEQUENCE
Chapter Issue 8, Jan 16 Installation Manual 5.9
18. If correct contact height is achieved go to Step 24.
19. Close the front printhead cover.
20. Press the System button.
21. Using the Incr. or Decr. buttons, increase or decrease the Contact Position
set height by 0.5mm (eg 5.0mm or 6.0mm).
NOTE
Normally the contact position is between 4mm and 8mm (nominally 6mm).
22. Select Move to Position, the ProFlow unit is driven to the position set.
23. Repeat Steps 17 to 22 to vary the set position until the correct contact height
is achieved.
24. Close the front printhead cover.
25. Press the System button.
26. Select Exit.
27. Select Exit.
28. Select Exit.
29. Select Back.
30. Select Unload Screen.
31. Open the front printhead cover.
32. Remove the shim
33. Remove empty transfer head.
34. Remove calibration screen.
35. Close the front printhead cover.
36. Press the System button.
Fitting the
Handheld Barcode
Reader
1. Select Shut Down and switch the mains isolator to OFF.
2. Gain access to the 4 port USB hub behind the front panel.
3. Connect the handheld barcode reader to a spare USB port on the hub.
4. Refit the front cover ensuring that the cable is routed between the MMI
monitor bracket and the front cover.
From PC
From M37
Touchscreen Monitor IR Receiver/Keyboard
Extension USB

POWER UP SEQUENCE
MACHINE POWER UP SEQUENCE
5.10 Installation Manual Chapter Issue 8, Jan 16
5. Power up the machine.
6. Select Maintenance.
7. Select Machine Setup.
8. Select Barcodes.
9. Select Handheld Barcode HW.
10. Select Fitted.
11. Select Accept.
12. Select Start Character.
13. Set the start character for the barcode (see barcode label below).
14. Select Accept.
15. Select Name Length.
16. Set the name length for the barcode.
17. Select Accept.
NOTE
The barcode set up is shown in code format. The code format for a barcode
of length 14 starting at character 4 would be:
###PPPPPPPPPPPPPP###
18. Select Back.
19. Select Back.
20. Select Back.
21. Use the documentation supplied with the reader to setup the language,
keyboard format and barcode symbology.