Retrofit instructions: Besi JTF2 (Traystak feeder) SIPLAC E S-25 HM / S-27 HM / HS-50 / HS-60 / HF -series / X-series 11/2006 Edition 38 : Use the 8.4 mm drill bit to drill a shallow c ounter sink through the drilling ho…

Retrofit instructions: Besi JTF2 (Traystak feeder) SIPLACE S-25 HM / S-27 HM / HS-50 / HS-60 / HF-series / X-series
11/2006 Edition
37
2.7 Retrofit the Besi adapter
There are 2 ways to fix the adapter plate to the table. Ideally, it should be fixed without clamp and
using screws (no risk of head crash). 2
The table should be removed from the machine for drilling. 2
After drilling, the table should be cleaned thoroughly and all drilling swarf removed. 2
For HS and S tables, the adapter or adapter with feeder can also be installed outside the machine.
For S component trolleys on HF-series / X-series, on the other hand, the adapter or adapter with
feeder must be installed with the table retracted. 2
The table must be free of dirt, components, etc, before the adapter is attached. 2
2.7.1 Drilling the fixing hole
The drilling template is not the same width as the adapter. 2
The table must be outside the machine and must be unplugged. 2
: To prepare the hole, place the drilling template at the desired position (which must fit with the
SIPLACE tape guide channel special design).
2
Drilling template
Drilling distance 173,8 mm

Retrofit instructions: Besi JTF2 (Traystak feeder) SIPLACE S-25 HM / S-27 HM / HS-50 / HS-60 / HF-series / X-series
11/2006 Edition
38
: Use the 8.4 mm drill bit to drill a shallow countersink through the drilling hole as a marker for
the 4 mm drill bit.
: Drill a hole with a depth of about 20 mm into the table with the 4 mm bit.
: Drill the hole with the 8.4 mm bit.
: Remove any burrs with the countersink.
: Use the thread cutter and the cutting oil to cut an M10 thread in the hole
(thread deepness about 10 - 15 mm).
: Repeat the process as required for the Traystak feeder to be fitted.
: Clean the table.
2.7.2 Without clamp, with hole
: Unplug the table and dock it out of the placement machine.
: Remove the clamp on the adapter plate.
: Position the adapter at the relevant position.
: Use the two outer screws to adjust the adapter so that it lies flat on the table's magnetic rail.
They are provided to prevent the magnetic rail being damaged when you tighten the screws
on the adapter.
2
With gap: WRONG!!!
Without gap: RIGHT!!!

Retrofit instructions: Besi JTF2 (Traystak feeder) SIPLACE S-25 HM / S-27 HM / HS-50 / HS-60 / HF-series / X-series
11/2006 Edition
39
: Screw the adapter in place with the M10 x 60 mm screw..
2
2
2.7.3 With clamp, without hole
The clamp does not work on the HF-series / X-series. 2
: Unplug the table and dock it out of the placement machine.
: Loosen the screws on the front of the adapter.
: Position the adapter at the desired position (which must fit with the SIPLACE tape guide chan-
nel special design).
2
2
2
2
2
2
2
2
Screw