2 WF3 JTF-ML2 Maintenance Remove tables (COT) (JTF-ML2) 5 min 1 / 1 C A U T I O N !  R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n a n c e Machin…

100%1 / 46
1 WF3 JTF-ML2 Maintenance Clean Cassette 5 min 4 / 4
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool: Wear Part: Consumables:
C3
www.asm-smt.com
19 Clean each cassette rib. 20 Load all trays back to the cassettes. 21 Lock safety latch.
2 WF3 JTF-ML2 Maintenance Remove tables (COT) (JTF-ML2) 5 min 1 / 1
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool: Wear Part: Consumables:
www.asm-smt.com
1 Press stop button. 2 Open the cover. 3 Press and hold COT button to undock
table.
4 Remove COT.
www.asm-smt.com