stopper for HF-series for processing area 1.pdf - 第14页
1 Assembly instructions Special design Stopper for pl acement are a 1 (00166322-01) SIPLACE HF-series SIPLACE 06/2007 Edition 14 : Disconnect the existing 4mm hose on the right side of the air-sp litter and reconnect the…

SIPLACE 1 Assembly instructions Special design Stopper for placement area 1 (00166322-01) SIPLACE HF-series
06/2007 Edition
13
: Pull out the air hose like shown on the pictures below.
1
1

1 Assembly instructions Special design Stopper for placement area 1 (00166322-01) SIPLACE HF-series SIPLACE
06/2007 Edition
14
: Disconnect the existing 4mm hose on the right side of the air-splitter and reconnect the hoses
with the provided branch as shown below. The picture shows the connection for single trans-
port, for dual transport use the second branch to get 2 air-supplies.
1
1
1
1
1
1
Existing hose
Branch
New hose to stopper
Existing hose
New hose to stopper
Branch
Air splitter

SIPLACE 1 Assembly instructions Special design Stopper for placement area 1 (00166322-01) SIPLACE HF-series
06/2007 Edition
15
: Pull the cable to the end of the cable trench and pass them through the cable bushing at the
end.
Use a taut wire to pull the cables through the hole!
1
: Pass the cables like shown on the pictures into the cable trench and pull them out at the front
to the board.
1