ReleaseNote_V3.41STD_R1.000_for_V30VGOS1.pdf - 第13页

YAMAHA MOTOR CO., LTD IM Operations Release Note(English) 2013/9/25 Ver Rev Num Ref Item Type Keyword Contents Result Doc 3.41 1.000 TTM36 26 Change YS Series Mounter Error Message The following error message has been mo…

100%1 / 19
YAMAHA
MOTOR
CO.,
LTD
IM
Operations
Release
Note(English)
2013/9/25
Ver
Rev
Num
Ref
Item
Type
Keyword
Contents
Result
Doc
3.41
1.000
-TM5247
13
Add
YSP20
Printer
For
more
efficiency,
it
has
been
modified
to
produce
boards
on
alternately
lane
1
and
2
when
the
following
conditions
are
satisfied.
1.
The
downstream
machine
is
a
single
lane
machine.
2.
Lane
1
and
2
are
the
same
in
all
of
the
following
parameters.
[Board
Name]
-
[Print]
-
[Board]
-
[Board
Size
-
[Print]
-
[Board]
-
[Board
Size
Y[mm]]
-
[Print]
-
[Board]
-
[Board
Size
Heightmm]]
-
[Print]
-
[Board]
-
[Print
Execution]
Modified
3.41
1.000
-TM5529
14
Add
YSP20
Conveyor
Out
"Preceding
Output
BA-OUT
Signal"
has
been
added.
According
to
this
function,
the
output
timing
of
BA-OUT
signal
changes
as
follows.
Enabled
:
When
requested
from
the
downstream
Disabled
:
When
a
board
arrives
at
the
carry-out
position
To
enable
this
function,
set
the
following
parameter
to
"Use".
1.
[Machine]
-
[Machine
Information]
-
[Installation
Setting]
-
[Preceding
Output
BA-
OUT
Signal]
Modified
3.41
1.000
TT8225
15
Change
Mounter
GUI
The
following
possible
cause
has
been
added
to
the
[Ea89:
NO
PARTS
FOR
USE]
error.
1.
The
[feeder
Remove]
button
tap,
and
the
feeder
is
removing.
Modified
3.41
1.000
TM5537
16
Change
Mounter
Side
view
camera
Execution
of
[Setup]
-
[Measure
Nozzles]
has
been
changed
from
by
each
head
to
by
each
table.
This
enables
checking
of
whole
a
table
at
once
on
the
[Measure
Nozzle
Check
Nozzle]
dialog.
"Ea7513:
nozzle
type
identification"
used
to
be
displayed
every
time
for
each
nozzle.
Modified
3.41
1.000
17
Change
Mounter
Pick
Position
Correction
The
initial
value
[Machine
Setting]
-
[Specification
Information]
-
[Pick
Position
Specification]
-
[Max
Sample
Num.]
has
been
changed
from
"3"
to
"20".
This
improves
the
Pick
Position
Correct
function,
and
pick
rate.
Modified
*
3.41
1.000
7M5530
18
Change
Mounter
Bring
Back
Parts
The
function
has
been
changed
to
allow
continuing
auto-running
when
"not
retry"
is
selected
after
the
following
errors
occur.
1.
"Ea944
:
SIDE
VIEW
CAMERA
:
BRING
BACK
AFTER
MOUNT"
2.
"Ea3270
:
BRING
BACK
ERROR
(AFTER
MOUNT)"
3.
"Ea3282
:
BRING
BACK
ERROR
(SCAN
CAMERA
ESCAPE)"
*
Machine
used
to
make
a
cycle
stop
with
"Ea947
:
CYCLE
STOP
"
and
"Ea948
:
SIDE
VIEW
CAMERA:
BRING
BACK
RETRY
CHECK
Modified
3.41
1.000
TM5880
19
Change
Mounter
Bring
Back
Parts
It
has
become
possible
to
retry
once
when
an
bring
back
parts
error
occurs
after
nozzle
changed.
zEa3270:
BRING
BACK
ERROR
(AFTER
MOUNT)"
is
displayed
then.
When
it
fails
again,
"Ea3045:
BRING
BACK
PARTS
ERROR"
is
displayed
as
before.
Modified
3.41
1.000
7M5538
20
Change
Mounter
History
It
is
modified
that
the
following
errors
are
counted
on
[Unit
log]
-
[Parts]
-
[Pick
Error
Counter].
1.
Ea29
:
PICK
UP
POSITION
ERROR
2.
Ea30
:
PARTS
DETECTION
ERROR
Modified
3.41
1.000
7M4528
21
Change
YS24(X)DL
Skip
Retry
Skip
Retry
has
been
supported
for
YS24(X)DL
Modified
3.41
1.000
TTB266
22
Change
YS24(X)DL
History
When
a
whole
machine
stops,
it
has
been
changed
to
output
the
following
information
about
of
both
lanes
to
[MIS]
-
[Board
Log].
It
used
to
record
only
the
lane
that
has
the
cause.
1.
Stop
Number
2.
Operator
Call
Time
3.
Recovery
Time
Modified
3.41
1.000
TM5919
23
Change
YC8
Machine
Setting
The
maximum
value
of
[Machine]
-
[Machine
Data]
-
[Mechanical]
-
[Position]
-
[Air
Blow]
-
[Timer]
has
been
changed
to
"50"
from
"7".
When
light
wight
insertion
parts
are
used,
parts
bring
back
tend
to
occur.
Therefore,
please
set
larger
value
here
when
a
bring
back
often
occurs.
Modified
3.41
1.000
TT6135
24
YS
Series
Mounter
Add
BadMark
The
Badmark
Transfer
function
has
been
modified
to
check
the
badmark
transfer
information
is
not
overwritten
between
when
board
carry-in
and
when
mounting.
In
case
that
the
badmark
transfer
information
is
overwritten,
the
following
error
is
displayed.
Recovery
function
is
OFF:
Displays
"Ea:13024:
Failed
to
transfer
bad
mark."
and
the
machine
stops.
Recovery
function
is
ON:
Records
"013023:
Badmark
result
transport
inside
data
is
NG.
"
on
[MIS]
-
[Error
Log],
(the
machine
doesn't
stop).
Modified
3.41
1.000
TTB662
25
Change
YS
Series
Mounter
GUI
Pictures
of
old
types
of
tape
feeders
were
displayed
on
the
parts
information.
It
has
been
changed
so
that
the
individual
picture
is
not
displayed,
since
there
is
not
much
difference
at
the
shape
of
the
newest
feeders.
Modified
MDOC-VG30-00001
12/19
YAMAHA
MOTOR
CO.,
LTD
IM
Operations
Release
Note(English)
2013/9/25
Ver
Rev
Num
Ref
Item
Type
Keyword
Contents
Result
Doc
3.41
1.000
TTM36
26
Change
YS
Series
Mounter
Error
Message
The
following
error
message
has
been
modified.
1.
"Ea30150/Ea30151:
Parts
empty
(Continue
to
Run)"
1)
Buzzer
sound
has
been
added.
2)
Display
of
feeder
set
positions
has
been
enlarged.
3)
Parts
Name
and
Comment
have
been
added.
2.
"Ea89:
NO
PARTS
FOR
USE"
1)
Parts
Name
and
Comment
have
been
added.
Modified
3.41
1.000
TM5699
27
Change
YS
Series
Mounter
Monitor
The
pictures
of
pallets
on
the
[monitor]
-
[production]
screen
have
been
changed.
Each
pallet
blinks
in
yellow,
when
they
become
empty.
Modified
3.41
1.000
7M5957
28
Change
YS
Series
Mounter
Return
to
origin
It
has
been
modified
to
display
"Ea
12988:
Do
you
start
Retum-to-Origin
of
Linear
Axis?"
when
a
routine
Linear
Origin
was
interrupted
by
an
interlock
or
an
emergency
stop.
*
In
this
case,
it
used
to
need
to
press
the
[Unit]
-
[Head]
-
[Linear
Origin]
button.
Modified
3.41
1.000
7M5944
29
Change
YS
Series
Mounter
History
Log
It
has
been
changed
to
output
the
table
number
to
[MIS]
-
[Error
Log]
-
[Details],
when
an
error
occurs
with
a
table
number
on
its
title
or
body.
Modified
3.41
1.000
TTB943
30
Change
YSH20
Dip
It
has
been
changed
to
do
the
checking
of
[Machine]
-
[Dipping
Station]
-
[Station
1
Size],
[Station
2
Size]
not
only
for
the
X
direction
but
also
the
Y
direction.
Modified
3.41
1.000
TM5750
31
Change
YSP20
Printer
The
movement
has
been
changed
in
condition
that
transfer
position
and
the
other
table
printing
position
are
interfering
each
other,
so
that
the
moving
efficiency
is
improved.
Before:
Either
of
printing
or
transfer
DOES
NOT
work
until
the
condition
becomes
safe.
After
Both
of
printing
and
transfer
DOES
work
at
the
same
time,
by
moving
the
Fix
Unit
away
to
the
safe
pedion.
Modified
3.41
1.000
TT8816
32
Change
YSP20
Conveyor
Out
Action
when
the
[Cancel]
button
is
pressed
during
transport
of
the
board
by
the
[Unit]
-
[Conveyor]
-
[Carry
In],
has
been
changed
as
follows.
Before
:
Immediate
Stop
After
:
The
machine
stops
after
completing
the
operation
in
progress
Modified
3.41
1.000
E5012
33
Change
Printer
PSC
The
timing
to
stop
the
machine
was
changed
when
solder
runs
out.
before:
Immediately.
after
After
printing
on
the
machine
cover
side
is
completed.
Modified
3.41
1.000
TT8837
34
Change
Printer
Board
data
The
following
symbols
and
characters
have
become
possible
to
use
at
printer,
same
as
mounter.
1.
[Print]
-
[Board]
-
[Board
Comment]
2.
[Mark]
-
[Name]
3.
[Mark]
-
[Comment]
before
:
_
after:
_!#$%&¥,¥¥-F-3g)0flD:.'"*<>?/|;
The
following
text
will
be
saved
to
"一"
when
save
characters
to
"txt"
format
board
data.
Replace
target
characters
:",
,丁,
"/"
Replace
the
characters
to
to
not
break
the
board
data.
Modified
3.41
1.000
TP3319
35
Change
Optimizer
Optimization
Optimization,
in
case
that
number
of
nozzles
specified
on
[Optimizer]
-
[Maintenance]
-
[Nozzle
Number
Information]
is
less
than
the
heads
on
machine,
has
been
improved.
Modified
3.41
1.000
TT8474
36
Change
All
Machine,
AIIY.
FacT
Edit
window
On
the
[Parts]
and
[Mark]
screen,
the
edit
status
when
the
focus
is
removed
has
been
changed
as
follows.
Before:
fixed
After
canceled
Modified
3.41
1.000
TT8508
37
Bug
All
Machine
Vision
Cursor
Teach
Under
the
following
conditions,
there
was
a
bug
that
one
click
of
the
arrow
button
made
the
axis
move
twice
on
the
[Unit]
-
[Axis]
screen.
1.
[Unit]
-
[Axis]
-
[Step
Mode]
is
"ON"
2.
Movement
distance
is
"0.5
mm"
or
less.
3.
The
arrow
button
is
kept
clicked
on
for
100msec
or
more.
Fixed
3.41
1.000
TTB375
38
Bug
Mounter
Application
Launch
On
machines
equipped
with
an
auto
nozzle
changer,
there
was
a
bug
that
"Ea151:
CHECK
THE
NOZZLE
TYPE"
or
"Ea192
:
CONFIRM
NOZZLE
TYPE"
unnecessarily
occurred
when
a
board
was
loaded
at
the
first
time
after
power-on.
Fixed
3.41
1.000
TTB398
39
Bug
Mounter
Interlock
When
an
interlock
error
occurred
on
a
multi-table
machine,
there
was
a
bug
that
any
error
message
was
not
displayed
until
mounting
on
the
other
table
was
completed.
*
It
is
a
display
problem.
Originally
it
is
displayed
immediately.
Fixed
MDOC-VG30-00001
13/19
YAMAHA
MOTOR
CO.,
LTD
IM
Operations
Release
Note(English)
2013/9/25
Ver
Rev
Num
Ref
Item
Type
Keyword
Contents
Result
Doc
3.41
1.000
TTB340
40
Bug
Mounter
Co
planarity
When
[Parts]
-
[PartsAcjj]
-
[Test]
was
executed
under
the
following
conditions,
there
was
a
bug
that
recognition
pictures
were
unclear
or
wrong
pictures
were
displayed.
1.
[Machine]
-
[Installation
Setting]
-
[Co-Planarity
Checker]
is
set
to
other
than
"None".
2.
[Board]
-
[Board]
-
[3D
Co-Planarity]
is
set
to
"Use".
3.
[Parts]
-
[Basic]
-
[Alignment
Group]
is
set
to
"Ball".
4.
[Parts]
-
[Basic]
-
[Alignment
Type]
is
set
to
"Simple
BGA".
5.
[Parts]
[Vision]
-
[3D
Co-Planarity
Threshold
(um)]
is
set
to
other
than
"Not
Use".
Fixed
3.41
1.000
TT8887
41
Bug
Mounter
Side
view
camera
There
was
a
bug
that
a
mount
failure
occurred
when
Halfway
Continue
was
performed
through
the
following
procedure.
1.
"Ea944:
SIDE
VIEW
CAMERA
:
BRING
BACK
AFTER
MOUNT"
occurs.
2.
Close
the
error
dialog,
(not
clear)
3.
Press
the
[RESET]
button.
Fixed
3.41
1.000
TTB531
42
Bug
Mounter
Tray
Through
the
following
procedure,
there
was
a
case
the
hook
moved
at
acceleration
of
"NORMAL"
regardless
of
the
[Machine
Data]
-
[Tray
Changer]
-
[Position]
-
[Auto
Tray]
-
[Hook]
-
[Acceleration/Deceleration
(%)]
setting.
1.
Set
a
pallet
on
[Unit]
-
[Auto
TC]
-
[Pallet
Set]
.
2.
Store
the
pallet
through
either
of
the
following
procedures.
1)
Press
the
[RESET]
button.
2)
Open
the
board
data.
3)
Start
warming
up.
4)
Tum
the
power
off.
5)
Open
the
ATS
door
switch.
Fixed
3.41
1.000
TT8411
43
Bug
Mounter
Vision
Cursor
Teach
When
Vision
Cursor
Teach
was
performed
on
a
multi-table
machine,
there
was
a
bug
that
the
table
stayed
at
the
teach
position
after
Vision
Cursor
Teach,
so
that
the
other
table
couldn't
move.
*
It
has
been
modified
to
move
the
table
away
so
that
it
will
not
bother
the
next
action.
Fixed
3.41
1.000
SSI
7386
44
Bug
Mounter
Feeder
There
was
a
bug
that
top
tape
of
SS
Feeder
occasionally
broke
under
the
following
condition.
1.
The
feeder
has
been
driven
w
h
the
setting
of
[Parts]
-
[Basic]
-
[Feed
Speed]
set
to
"90%"
or
less.
Fixed
3.41
1.000
TT8162
45
Bug
Mounter
Random
ball
There
was
a
bug
that
the
value
of
"Std.
Ball
Diameter"
of
"Random
Ball
Edit"
was
set
on
"Lead
Width
N1"
under
the
following
conditions.
1.
[Parts]
-
[Shape]
1)
[Alignment
Group]
is
set
to
"Special"
2)
[Parts]
-
[Shape]
-
[Alignment
Type]
is
set
to
"Special"
3)
[Parts]
-
[Shape]
-
[Base
Alignment]
is
set
to
"FlipChip"
4)
[Parts]
-
[Shape]
-
[Algorithm]
is
set
to
"2:
Simple
High
Speed",
"3:
Special
3",
"4:
Special
4",
"5:
Special
5"
or
"6:
Special
6"
5)
[Parts]
-
[Shape]
-
[Edit
Mode]
is
set
to
"Details"
2.
Open
the
[PartsAdj]
-
[Random
Ball]
screen,
then
press
the
[OK]
button.
Fixed
3.41
1.000
TT8215
46
Bug
Mounter
Cleaning
Blow
Through
the
following
procedure,
nozzle
shaft
blow
was
not
performed
and
the
machine
slept
1.
Press
the
[Unit]
-
[Head]
-
[Cleaning
Blow]
button
to
start
nozzle
shaft
blow.
2.
Press
the
[Cancel]
button.
3.
Press
the
[Unit]
-
[Head]
-
[Cleaning
Blow]
button.
Fixed
3.41
1.000
TTB893
47
Bug
Mounter
Double
Mounting
There
was
a
bug
that
a
double
mounting
occurred
through
the
following
procedure.
1.
"Ea944:
SIDE
VIEW
CAMERA
:
BRING
BACK
AFTER
MOUNT"
occurs.
2.
Clear
the
error,
the
[Retry
Setting]
dialog
appears,
then
select
"Not
Retry".
3.
On
the
[Dumping
part]
dialog,
press
the
[Cancel]
button
to
stop
halfway.
4.
Start
auto-running.
Fixed
3.41
1.000
TTB928
48
Bug
YS12
Series
Machine
Setting
On
[Machine]
-
[Specification
Information]
-
[Plate
Specification]
-
[Set
No.1],
the
following
feeders
were
set
as
unsettable.
Originally,
they
should
be
settable.
24mm
Tape
/
32mm
Tape
/
44mm
Tape
/
56mm
Tape
/
72mm
Tape
/
88mm
Tape
Fixed
3.41
1.000
TTM05
49
Bug
YS12F,YG12
F,YS24X
Interlock
There
was
a
bug
that
"Ea2652:
INTERLOCK
ERROR"
occasionally
occurred
at
multi¬
camera
recognition
under
the
following
condition.
1.
[Parts]
-
[Pick]
-
[Pick&Mount
Vacuum
Check]
is
set
to
"SPECIAL
CHK".
Fixed
3.41
1.000
TT8290
50
Bug
YS24(X)DL
Side
view
camera
There
was
a
bug
that
the
side
view
recognition
failed
under
the
following
conditions.
1.
Click
the
[Monitor]
-
[Vision]
tab
during
auto-running.
2.
Click
another
tab
during
recognition.
Fixed
3.41
1.000
TTB312
51
Bug
YS24(X)DL
Signal
Tower
There
was
a
bug
that
the
signal
tower
blinked
at
starting
auto-running
under
the
following
conditions.
1.
Board
data
is
read
only
on
e
her
lane.
2.
[Board]
-
[Mount]
-
[Mount
Item]
is
set
to
"Skip"
and
no
feeder
is
set
Fixed
MDOC-VG30-00001
14/19