ReleaseNote_V3.41STD_R1.000_for_V30VGOS1.pdf - 第18页
YAMAHA MOTOR CO., LTD IM Operations Release Note(English) 2013/9/25 Ver Rev Num Ref Item Type Keyword Contents Result Doc 3.41 1.000 VC10051 Vis1301 003 91 Bug Printer Vision Under the following condition, there was a bu…

YAMAHA
MOTOR
CO.,
LTD
IM
Operations
Release
Note(English)
2013/9/25
Ver
Rev
Num
Ref
Item
Type
Keyword
Contents
Result
Doc
3.41
1.000
TTB781
78
Bug
YS
Series
Mounter,
YG12
Series
Dump
There
was
a
bug
that
the
dumping
speed
became
5%
of
standards
under
the
following
conditions.
1.
[Parts]
-
[Basic]
-
[retry
times]
is
set
to
except
"immediate
stopping".
2.
[Machine
Data]
-
[Mechanical]
-
[Position]
-
[Dump
Way]
-
[Dump
speed(%)]
is
set
to
except
"standard".
Fixed
3.41
1.000
TT8881
79
Bug
YS
Series
Mounter,
YG12
Series
History
Log
Under
the
following
conditions,
there
was
a
bug
that
no
list
was
displayed
on
the
[MIS]
-
[Program
log]
screen.
1.
Dual
lane
and
single
stage
machine.
2.
"Machine
Entire"
is
selected
on
[Lane
Select].
Fixed
3.41
1.000
TT8884
80
Bug
YSH20
Internal
Error
There
was
a
bug
that
an
internal
error
occasionally
occurred
during
board
data
loading.
1.
[Machine]
-
[Machine
Information]
-
[Installation
Setting]
-
[Mount
Irrfb.Mode]
is
set
to
"V3.0
Extended".
2.
[Board]
-
[Board]
-
[Running
Mode]
is
set
to
"Sequence".
3.
[Board]
-
[Sequence]
-
[Mode]
is
set
to
"Act".
Fixed
3.41
1.000
TTB846
81
Bug
YSH20
Operator
Level
There
was
a
bug
that
the
[Parts]
-
[Tray]
-
[Wafer]
-
[Wafer
Information]
dialog
didn't
work
according
to
the
operator
level.
Even
when
Wafer
Tray
check
boxes
on
[Setup]
-
[Software
Setting]
-
[Operator]
-
[Level
Edit]
were
off,
these
parameters
could
be
edited.
Fixed
3.41
1.000
7M5822
82
Bug
YSH20
Servo
There
was
a
bug
that
"Es94:
48V
motor
power
fail
(Low)"
occasionally
occurred,
when
the
[EMERGENCY
STOP]
button
was
pressed
while
LP-axis
of
Wafer
Tray
was
down.
Fixed
3.41
1.000
TT8719
83
Bug
YSH20
Halfway
Continue
There
was
a
bug
that
,
/Ea2741:
HALFWAY
CONTINUE
ERROR"
occurred
and
auto¬
running
did
not
start
through
the
following
procedure.
1.
Reset
the
machine
while
the
downstream
stage
is
performing
mounting.
2.
Press
the
[START]
button.
3.
Select
[No]
on
the
"Ea12622:
Halfway
Continue(Ea
12622)"
message.
4.
Insert
the
next
board,
and
reset
the
machine
while
the
upstream
stage
is
performing
mounting.
5.
Press
the
[START]
button.
6.
Select
[Yes]
on
the
"Ea
12622:
Halfway
Continue".
Fixed
3.41
1.000
TTB728
84
Bug
YSP
Interlock
Under
the
following
conditions,
there
was
a
bug
that
Main-Stopper
Axis
was
able
to
move
though
it
might
have
caused
an
interference
with
Board
Backup
Jig.
1.
The
Board
Backup
Jig
is
not
supported
for
High-Speed
Transfer
2.
Push-Up
is
not
lowered.
3.
Main
stopper
is
not
moved
back.
Fixed
3.41
1.000
TTB949
85
Bug
YSP
Interlock
There
was
a
bug
that
the
machine
was
moved
as
follows,
when
the
cover
of
upstream
and
downstream
machine
was
opened
during
W-axis
moving,
and
also
when
[Machine]
-
[Specification
Information]
-
[Safety
Specification]
-
[Upper
Lover
Cover
interlock]
was
enabled.
1.
It
takes
5
seconds
until
the
machine
stops
with
error,
after
the
cover
of
upstream
and
downstream
machine
was
opened.
(It
must
stop
immediately.)
2.
W-axis
moves
again
when
the
cover
of
upstream
and
downstream
machine
was
closed.
Fixed
3.41
1.000
TT8842
86
Bug
YSP
Operation
Panel
There
was
a
bug
that
displays
"PAUSE"
when
the
[START]
button
is
pushed,
even
though
printers
don't
have
the
"PAUSE"
function.
Fixed
3.41
1.000
TT8039
87
Bug
YSP
Under
the
following
conditions,
there
was
bug
that
"Ea
12881:
Repair
work
un-completing
after
a
serious
error"
occurred
and
auto-running
didn't
start
1.
Use
Printer
with
an
edge
clamp
fore
end
sensor
(Type2)
2.
"Ea8997
«
WARNING
>>
The
fixed
board
is
lost(Ea8997)"
occurs
during
auto-
running.
3.
The
board
is
taken
out
with
the
[Unit]
一
[Carry
Board
out]
button
after
the
mask
clamp
released.
Fixed
3.41
1.000
TT8870
88
Bug
YSP20
Backup
Pin
There
was
a
bug
that
"Ea29646:
FIX
UNIT
BRAKE
INTERLOCK"
wrongly
occurred
at
the
time
of
,
/Ea29618:
PIN
SENSOR
INTERLOCK"
that
occurs
when
an
unknown
otyect
is
detected
during
conveyor
width
adjustment
Fixed
3.41
1.000
TTB523
89
YSP20
Bug
Internal
Error
There
was
a
case
that
an
internal
error
rarely
occurred
at
board
carry-out.
Fixed
3.41
1.000
TT8241
90
Bug
Mounter,
M-
Tool
Remote
Control
There
was
a
bug
that
MIS
of
each
board
data
was
not
deleted
even
when
the
board
data
was
deleted
under
the
following
conditions.
1.
On
[Setup]
-
[Communication
data],
a
machine
w
祀
h
data
type
"YGX"
exists.
2.
On
the
Board
data
communication
RemoCon
dialog,
execute
[Delete]
or
delete
board
data
after
executing
[Receive]
Fixed
MDOC-VG30-00001
17/19

YAMAHA
MOTOR
CO.,
LTD
IM
Operations
Release
Note(English)
2013/9/25
Ver
Rev
Num
Ref
Item
Type
Keyword
Contents
Result
Doc
3.41
1.000
VC10051
Vis1301
003
91
Bug
Printer
Vision
Under
the
following
condition,
there
was
a
bug
that
"Ea871
1
:
PRINT
INSPECTION
DATA
ERROR"
occurred
when
loading
the
board
data.
1.
512
inspection
views
are
registered
on
[Inspection]
-
[View]
tab.
Fixed
3.41
1.000
TTB370
92
Bug
Optimizer
CT
Estimation
Under
the
following
8nd
祀
ions,
there
was
a
bug
that
a
cycle
time
was
calculated
without
feeding
time
so
that
the
estimated
cycle
time
was
shorter
than
actual.
1.
YG12Series,
or
YSSeries
mounter
is
used.
2.
Either
of
the
following
type
of
parts
is
used.
1)
Stick
(except
for
Multi-Stick)
2)
Hopper
bulk
Fixed
3.41
1.000
TTB779
93
Bug
Optimizer
CT
Estimation
Under
all
of
the
following
conditions,
there
was
a
bug
that
"Ea
17904:
Cycle
Time
Estimation
Error"
occurred
during
optimization
or
CT
estimation.
1.
The
machine
is
YG300
or
YG12Series
or
YSSeries
mounter
or
YSM40.
2.
[Machine
Data]
-
[Mechanical]
-
[Position]
-
[BadMark]
-
[TakeOver]
is
set
to
"Enable
(Leadoff)".
Fixed
3.41
1.000
TT9019
94
Bug
Optimizer
CT
Estimation
Under
the
following
conditions,
there
was
a
bug
that
"Ea
17904:
Cycle
Time
Estimation
Error"
occasionally
occurred
during
CT
estimation.
1.
The
machine
is
YS24DL,
YS24XDL,
or
YSM40.
2.
There
is
a
large
difference
in
number
of
mount
points
between
tables.
(ex.
A
table:
1
mount
point,
B
table:
2000
mount
point)
Fixed
3.41
1.000
TT90B1
95
Bug
Optimizer
CT
Estimation
On
the
following
conditions,
there
was
a
case
that
result
of
CT
estimation
was
over
estimated.
1.
The
board
data
is
combined
board.
2.
[Board]
-
[Board]
-
[Precede
Pick]
is
"Enable".
3.
[Board]
-
[Board]
-
[Mount
Mode]
is
set
to
"Parallel
Lanes".
4.
[Board]
-
[Board]
-
[Transfer
Mode]
is
set
to
"Asynchronous
Transfer".
5.
On
YS24,
or
YS24X
equipped
with
Nozzle
Station.
Fixed
3.41
1.000
TT8857
96
Bug
Optimizer
Internal
Error
There
was
a
bug
that
an
internal
error
occasionally
occurred
during
optimization,
when
two
or
more
nozzle
types
were
chosen
in
[Machine]
-
[Specification
Information]
-
[Mount
Nozzle
Specification]
-
[Nozzle
Type].
Fixed
3.41
1.000
TTB549
97
Bug
Optimizer
Optimization
When
all
of
the
following
conditions
were
satisfied,
there
was
a
bug
that
an
internal
error
occurred.
1.
[Set
optimization
parameters]
-
[Exec
Option]
-
[Decide
pallet
number
automatically]
is
enabled.
2.
Number
of
the
pallets
to
use
for
optimization
are
over
those
of
pallets
storable
in
the
tray
changer.
3.
The
value
of
[Machine
Property]
-
[Machine
Data]
-
[Tray
Changer]
-
[Position]
-
[Pallet
Pitch]
is
smaller
than
"0.00".
Fixed
3.41
1.000
TT8519
98
Bug
Optimizer
Optimization
There
was
a
bug
that
"Parts
Name"
was
not
displayed
when
"Ea24620
BOARD
DATA
ERROR"
occurred.
1.
The
parts
are
not
applicable
for
offset
re8gn
祀
ion,
or
[Parts]
-
[Basic]
-
[Vision]
-
[Offset
Resgnition]
is
"Impossible".
2.
[Parts]
-
[Basic]
-
[Side
View]
-
[Side
View
Camera]
is
"Normal
Mode"
or
"Detail
Mode".
Fixed
3.41
1.000
TTB665
99
Bug
Optimizer
Optimization
There
was
a
bug
that
"Ea17901:
optimization
error"
sometimes
occurred
and
optimization
failed,
when
the
nozzles
set
on
[Optimizer]
-
[Maintenance]
-
[Nozzle
Number
Information...]
was
less
than
the
number
of
heads
of
a
machine
,
Fixed
3.41
1.000
TTB738
100
Bug
Optimizer
Optimization
There
was
a
bug
that
//Ea3945:HEAD
SHAFT
DIAMETER
ERROR"
occurred,
when
there
was
a
table
with
[Machine
Information]
-
[Machine
Variation
Setting]
-
[Head
Variation]
set
to
"None".
Fixed
3.41
1.000
1P3431
101
Bug
Optimizer
Optimization
There
was
a
case
that
the
parts
performing
Feeder
MACS
was
set
to
out
of
the
softlim
祀
of
the
moving
camera.
Fixed
3.41
1.000
TT8977
102
Bug
Optimizer
Optimization
Under
the
following
conditions,
there
was
a
bug
that
optimization
took
quite
long
time.
1.
DualLane
Line
2.
Target
board
data
is
combined
board
data
3.
Target
board
data
contains
parts
with
[Parts]
-
[Parts
Group
No.]
other
than
"0"
*
The
more
mount
points
and
parts
with
other
than
"0"
on
[Parts
Group
No.]
there
are,
the
much
longer
the
optimization
took.
Fixed
3.41
1.000
TTB998
103
Bug
Optimizer
Optimization
There
was
a
case
that
an
application
abnormal
end
occurred
while
optimization
when
the
board
data
included
multi-stick
feeder
without
any
mount
point
Fixed
MDOC-VG30-00001
18/19

YAMAHA
MOTOR
CO.,
LTD
IM
Operations
Release
Note
Option(English)
2013/9/25
Ver
Rev
Num
Ref
Item
Type
Iteyword
Contents
Result
Doc
3.41
1.000
7M5650
7M5651
7M5652
7M5769
7M5770
7M5910
1
Add
YS
Series
Mounter,
YSP
Op003:
Auto
Program
Change
Over
Auto
Program
Change
Over
has
been
supported
for
the
production
lot.
In
addition
to
"ASSY"
and
"Surface.",
"Production
Lot"
has
been
added,
so
that
it
has
becomes
possible
to
auto
perform
program
change
over
by
selecting
/
,Productior)Lot/,.
Modified
*
3.41
1.000
TT89O4
2
Bug
Mounter
Op001:
Remain
Counter
Op002:
Setup
Verification
With
z
,Op001:
Remain
Counter"
or
"Op002:
Setup
Verification"
used,
there
was
a
bug
that
an
application
abnormal
end
occurred
when
the
following
error
was
closed
with
the
[Close]
button
then
board
data
was
saved.
1
.Ea1
2476/Ea25142/Ea25143:
Parts
remain
warning
2.Ea25504/Ea251
46/Ea25
1
47:
Alternative
Parts
Empty
Warning
3.Ea87/Ea365:
NO
PARTS
FOR
USE
4.Ea29082:
Auto
Tray
Changer
Parts
Empty
5.Ea29083:
Ext
Tray
Changer
Parts
Empty
Fixed
3.41
1.000
TT8109
3
Bug
Mounter
Op002:
Setup
Verification
Under
either
of
the
following
conditions,
there
was
a
bug
that
"Ea25573:
Set
Number
Error"
occurred
at
the
time
of
reading
Parts
ID
so
that
setup
was
failed.
1.
Set
the
"ExtTC"
parts
as
"NorrUsed
Parts"
to
ATS.
2.
Set
the
"Auto
TC"
parts
as
"Non-Used
Parts"
to
Ext
Tray
Changer.
It
is
fixed.
3.41
1.000
TT8844
4
Bug
Mounter
Op002:
Setup
Verification
When
ReellD
was
not
used,
there
was
a
bug
that
LotID
was
not
switched
even
when
the
parts
are
exchanged.
Fixed
3.41
1.000
TT8585
5
Bug
Mounter
Op005:
Product
Traceability
There
was
a
bug
that
information
of
the
previous
Reel
ID
was
output
to
"Lot
parts
log",
even
after
spliced
to
the
new
one
by
performing
"Splicing
point
check".
Fixed
3.41
1.000
rrazn
6
Bug
YS2<X)DL
Op003:
Auto
Program
Change
Over
There
was
a
bug
that
the
planed
production
count
was
not
updated
under
the
following
conditions.
1.
The
board
ID
of
combined
board
data
is
read
on
one
lane.
2.
Both
lanes
perform
the
automatic
program
changeover.
The
planed
production
count
of
the
lane
which
did
not
read
board
ID
was
not
updated.
*This
is
onlv
a
disDlav
Droblem.
It
is
fixed.
3.41
1.000
TT8985
7
Bug
YS2<X)DL
Op003:
Auto
Program
Change
Over
There
was
a
bug
that
an
internal
error
occurred
through
the
following
procedure.
1.
Display
either
of
the
following
dialogs.
1)
[Monitor]
一
[Production]
一
[Auto
Pgm
Change]
-
[Manual
Select]
-
[Manual
Select]
2)
[Monitor]
-
[Production]
-
[Auto
Pgm
Change]
-
[KANBAN]
-
[Input
Kanban]
2.
Select
data
without
program
name
from
the
program
list
Fixed
3.41
1.000
TT9013
8
Bug
YS2<X)DL
Op012:Type1
Op013:Type2
Op014:TypeN
When
"Module
Stop(Op012:Type-1/Op013:Type-2)/,
or
"Board
Data
Change
without
Stop(Op014:Type-N)"
is
used,
a
nozzle
touched
the
feeder
cover
through
the
•following
procedure.
1.
Stop
the
machine
that
is
working
only
on
one
lane.
2.
Press
the
[Cancel]
button
before
the
machine
completely
stops.
*
The
[Cancel]
button
has
become
disabled
while
the
machine
completely
stops.
Fixed
3.41
1.000
TT6372
9
Bug
YS2<X)DL
Op013:Type2
Under
the
following
conditions,
there
was
a
bug
that
z
,Ea7340
:
Specified
number
of
Board
is
finished"
occurred
at
starting
auto-running.
1.
Input
number
into
[Setup]
-
[Produced]
on
both
lanes.
2.
The
number
of
planned
production
has
been
completed
on
one
lane.
3.
The
"Module
Stop"
is
OFF.
Fixed
3.41
1.000
TT7593
10
Bug
YS
Series
Mounter
Op014:TypeN
There
was
a
bug
that
the
previous
board
name
was
displayed
on
[Lane
2]
of
the
[Board
data
select]
or
[Board
data
save]
screen.
1.
Open
the
[Board
data
select]
screen,
and
load
a
combined
board.
2.
Open
the
[Create
Board
Data]
screen,
and
create
a
new
board.
3.
Open
the
[Board
data
select]
screen
or
the
[Board
data
save]
screen.
It
is
fixed.
3.41
1.000
TT8988
11
Bug
YS
Series
Mounter
Op002:
Setup
Verification
There
was
a
bug
that
the
yellow
signal
tower
does
not
tum
off
through
the
following
procedure.
1.
Clamp
the
cart
off
to
tum
the
setup
status
into
"not
completed".
2.
Clamp
on
the
cart
with
setup
parts
on
to
tum
its
status
into
"completed".
Fixed
3.41
1.000
TT8621
12
Bug
YSP
Op003:
Auto
Program
Change
Over
There
was
a
bug
that
an
internal
error
occurred
when
a
board
was
inserted
from
the
exit
of
the
extended
conveyor
during
auto-running.
In
this
case,
/zEa25623:Take
over
file
write-in
error"
should
be
displayed..
Fixed
3.41
1.000
TT8879
13
Bug
Printer
Op003:
Auto
Program
Change
Over
There
was
a
bug
that
"Ea12051
Machine
control
stopped""
occurred
through
the
•following
procedure
after
"Ea8842:
Unknown
board
is
detected
at
the
Printing
position
sensor"
occurred.
1.
Clear
the
error.
2.
Press
the
[START]
button,
without
pressing
the
[RESET]
button.
*
Originally,
,,Ea8842/,
should
be
displayed
again.
Fixed
MDOC-VG30-00001