ASM-SMT-Technical Conditions of Order and Deliveries (TCOD).pdf - 第32页

32 www.asm-smt.com - ad 1): Company name “ASM AS” - ad 2): The part number with FS (functional version) is specified in the manufacturing documentation. - ad 3): The serial number must be specified if unique tracea bilit…

100%1 / 48
31 www.asm-smt.com
9.6.3.3. Electrical / electronic assemblies (printed circuit boards)
Labeling methods:
For the entire assembly: Adhesive label
For the board: Print, engraving, laser printing, in Cu (in layout); other methods as agreed with ASM
AS. The location of the labeling is specified in the component mounting diagram (see
example below).
The UR logo, the manufacturer logo, the board type and the flammability class
according to UL 94 must be etched on the board as part of the layout.
The locations of the labeling are defined in the component mounting diagram of the printed circuit board. Each location is
identified with a letter code (A, B, C) and an outline.
In case of difficult space conditions, the contents may be distributed among several locations (partial labeling B1 .. Bn).
Fully designed labeling layout for printed boards (A = Identification label)
32 www.asm-smt.com
- ad 1): Company name “ASM AS”
- ad 2): The part number with FS (functional version) is specified in the manufacturing documentation.
- ad 3): The serial number must be specified if unique traceability is required.
- ad 4): The alphanumerical date code is defined in Subsection 9.6.4.
- ad 5): The factory code is specified by Purchasing.
In case of difficult space conditions, the contents may be distributed among several locations (partial labeling
A1 .. An).
Externally developed standard printed boards
- ad 1): The company name (currently ASM Assembly Systems) is specified in the order text.
- ad 2): The item number with FS (functional version) is specified in the manufacturing documentation.
In addition to the labeling shown, the supplier must mark these products with his manufacturer name or manufacturer
code, type designation, serial number and/or the manufacturing date.
2)
3)
4)
5)
33 www.asm-smt.com
9.6.3.4. Prefabricated cables, wires and pneumatic lines
Attaching labels to cables:
As a rule, labels must be attached to both ends of the cable. For cables with a length under 200mm, one label that shows
both connector designations and is located in the middle is sufficient.
The labeling must always remain fully legible in the installed condition of the cable. For very thin cables (e.g. individual
conductors), the label shall be attached in the form of a tag, where the labeling field shall also be covered with the
transparent part of the label.
Basic information about the prefabrication and the required identification features with respect to cables, lines, connectors
and wiring are specified in the order documentation.
Unless otherwise specified in the order documentation, the labels shall be attached in the following locations:
on stripped cable: on the cable jacket at 2030mm from the end of the jacket
on ribbon cable: on the cable at 2030mm from the connector
- ad 1): Company name “ASM AS”
- ad 2): Item number with (functional version) of the corresponding prefabricated cable.
- ad 3): The alphanumerical date code is defined in Subsection 9.6.4.
- ad 4): The factory code is specified by Purchasing.
- ad 5): The connector designations are specified in the corresponding documents for the item. The connector
designation is eliminated for cable ends without installed connector (see also paragraph on “connector markings”).
Alternative marking (without label):
As an alternative to labels, markings on the cable jack, on individual conductors and on connectors are also permissible.
The general requirements such as legibility, resistance to abrasion and resistance to solvents and contamination must be
met. Such markings must not cause any damage.
Marking sequence / location:
Markings on cable jack:
The connector designations must be located next to the corresponding connector, followed by the company name, the
item number with functional version (FS), the manufacturer ID and the manufacturing date (coded). The individual
indications shall be separated by spaces.
Example: [Connector] [approx. 10mm] x5rh_ASM AS_03001234-01_XXX_RO30
Beginning and end of markings: approx. 10mm from beginning or end of cable jack, outside cable ties and legible in
assembled condition.