SOM-1750-001.pdf - 第12页

Tg0967-PM-SO 3. Example of Data Output (Component Shortage Output Function) (Machine to External Host Computer) 0309-001 11 3. Example of Data Output (Component Shortage Output Function) (Machine to External Host Compute…

100%1 / 17
Tg0967-PM-SO
2.1 Component Shortage Data Output Function
0309-001 10
Detailed Information
Data Description
Type (Machine Status)
Error Pickup Error (*5) 0x31: COMP. MISSING Component Shortage
(A) (SENSOR) Pickup Error
0x33: COMP. MISSING (Thickness : less than 0.15 mm)
(RECOG.)
0x35: SHORTAGE OF If the tape end detection function is not
COMP. used, this error will not be indicated.
When the tape end is detected three
times and no component is detected by
the sensor, the tape end detection func-
tion indicates this as an error.
Error Pickup Error (*6) 0x32:COMP. VERTICAL Pickup Error Wrong Pickup Posture (Vertical Pickup)
(B) (SENSOR) or Wrong Tape End Detection due to
Excessive Thickness
0x33: COMP. MISSING Component Falling (Thickness: 0.15 mm or more)
(RECOG.) during
Feeding
0x34: COMP. RECOG. Component Posture
ERROR Error
Wrong Component
Loading
Data Error
0x37
0x38: COMP. Wrong Component The component thickness is too thin.
THICKNESS
(SENSOR)
0x39
Error Alternate Mode 0x31 to 0x39 (*7) Same as the above- The objective feeder alternate data for
(Unit) described Pickup Error linking is also transmitted collectively at
the same time.
Alarm Alternate Mode 0x31 to 0x39 (*7) Same as the above-
(Feeder) described Pickup Error
Recovery Mode 0x31 to 0x39 Recovery Generation
Component Tape End Detection The tape end was detected.
Shortage Alarm
Table 2
Cause Remarks
(*5) Determined as an error according to the reached counts specified
in the component library data "Error Process Data 1".
(*6) Determined as an error according to the reached counts specified
in the component library data "Error Process Data 2".
(*7) The objective feeder alternate data for linking is also transmitted
collectively while an error at the last alternate feeder slot is being
sent out.
Refer to the example of the data output.
Tg0967-PM-SO
3. Example of Data Output (Component Shortage Output Function) (Machine to External Host Computer)
0309-001 11
3. Example of Data Output
(Component Shortage Output Function)
(Machine to External Host Computer)
Pattern Program Data (Component Data) Table 3
Feeder
Component ID
Feeder Alternate
Slot Nos. Mode Feeder No.
101 C1005T05B0 ENABLE 103
102 ALC4343-BOMAT DISABLE 000
103 C1005T05B0 ENABLE 104
104 C1005T05B0 ENABLE 105
105 C1005T05B0 ENABLE 106
106 C1005T05B0 DISABLE 000
In the case of the above-described pattern program data, the results of
the data output (from the machine to the external host computer) will be
as follows.
(1)
(2)
(3)
(4)
(5)
Fig. 5
Tg0967-PM-SO
3. Example of Data Output (Component Shortage Output Function) (Machine to External Host Computer)
0309-001 12
(1) Component Shortage Error at Feeder No. 101
The message "Feeder Alternate Mode Activated" appears on the
"Information" display.
The component shortage (alarm) data is transmitted to the external
host computer at the same timing.
The machine moves to Feeder No. 103 (destination for the alter-
nate mode) for component picks. (*1)
(2) Component Shortage Error at Feeder No. 103
The message "Feeder Alternate Mode Activated" appears on the
"Information" display.
The component shortage (alarm) data is transmitted to the external
host computer at the same timing.
The machine moves to Feeder No. 104 (destination for the alter-
nate mode) for component picks.
(3) Component Shortage Error at Feeder No. 104
The message "Feeder Alternate Mode Activated" appears on the
"Information" display.
The component shortage (alarm) data is transmitted to the external
host computer at the same timing.
The machine moves to Feeder No. 105 (destination for the alter-
nate mode) for component picks.
(4) Component Shortage Error at Feeder No. 105
The message "Feeder Alternate Mode Activated" appears on the
"Information" display.
The component shortage (alarm) data is transmitted to the external
host computer at the same timing.
The machine moves to Feeder No. 106 (destination for the alter-
nate mode) for component picks.
(5) Component Shortage Error at Feeder No. 106
The error message "COMP. MISSING (SENSOR)" is issued be-
cause component shortage errors have occurred at all objective
feeder Nos. for alternate linkage and the machine stops temporarily.
The component shortage (error) data is transmitted to the external
host computer at the same timing. In this case, the feeder slot data
for all objective slots for alternate linkage is sent out at the same
time.