Installation Manual SIPLACE Setup Center RF 2.1 2 System Components and Configurations Edition 09/2005 EN 2.1 Overview of System Components 11 – Dat abase ver sion The database will be upgraded by the inst allation. In t…

2 System Components and Configurations Installation Manual SIPLACE Setup Center RF 2.1
2.1 Overview of System Components Edition 09/2005 EN
10
2
Fig. 2 - 1 Decision Tree for SIPLACE Setup Center Database
Questions:
– Do the packaging units have Unique ID barcodes?
Each packaging unit in the factory must be marked with a unique barcode. It is possible that
the unique ID is part of a combined barcode. 2
– Do you validate the setup in a pre-setup area?
The pre-setup area is used to validate the setup for correctness and completeness. The vali-
dated tables are docked to the production line(s) for use. 2
– Local database (MSDE)
This scenario does track the numbers of components on each packaging unit. The current
number of components are "remembered" when the packaging unit is teared down. If the pack-
aging unit is moved to another line the other Setup Center system does not know this reel and
will start with the start quantity. Therefore the operator need to check each partially fractured
packaging unit he gets from the stock and need to adjust the quantity if necessary. 2
This scenario offers a higher amount of operation safety, because the SIPLACE Setup Center
and a local MSDE database are installed to different computers for each production line. If one
component of SIPLACE Setup Center encounters an error, only one production line is af-
fected. 2
– Central database
The SIPLACE Setup Center database can be installed to any available Microsoft SQL Server
2000 (SP3a). In this case, the customer is responsible to set up a backup & recovery strategy
and must provide an operating Microsoft SQL Server 2000 (SP3a). 2
No Yes
No Yes
Local Database
(MSDE)
Central Database
Do you validate the setup
in a pre -s etup area ?
Do the packaging units
have Unique ID barcodes ?

Installation Manual SIPLACE Setup Center RF 2.1 2 System Components and Configurations
Edition 09/2005 EN 2.1 Overview of System Components
11
– Database version
The database will be upgraded by the installation. In this step, the current verification data will
be deleted and the setups must be verified again after the installation. All data that is connected
to unique IDs (Unique IDs for packaging units and change over tables) will be kept in the da-
tabase. This means that after re-verifying the fill-levels of the packaging units are restored. 2
Note
The database version for SIPLACE Setup Center RF 2.1 is 1.0.1.4.
The database version for SIPLACE Setup Center RF 2.0 is 1.0.1.3. 2
Note
When working with identical component lots (without Unique IDs), the fill-levels of the packaging
units must be restored manually after the installation (fill-level corrections). 2
2.1.1.2 Setup Center GUI
It is recommended to install SIPLACE Setup Center GUI once for each line. With the "central da-
tabase" scenario these can use the same database at the same time. 2
It is recommended to use two barcode scanners per line and SIPLACE Setup Center GUI instal-
lation. 2
2.1.1.3 SIPLACE Pro Configuration
It is recommended that at least SIPLACE Pro Interface (SPI) is installed on the system. SIPLACE
Setup Center works with SIPLACE Pro 2.x and SIPLACE Pro 3.x, but it uses different files, de-
pending on the SIPLACE Pro version. 2
Further information about this is given in the according installation steps for SIPLACE Setup
Center GUI. 2
2
2 System Components and Configurations Installation Manual SIPLACE Setup Center RF 2.1
2.1 Overview of System Components Edition 09/2005 EN
12