TK26522.Chip Vacuum Check.pdf - 第11页

S M T S o f t w a r e E n g i n e e r i n g G r o u p I M O p e r a t i o n s Y A M A H A M O T O R C O . , L T D MDOC-SOFT50395 7.2 Nozzle Specifications at update This function is available in the following software ve…

100%1 / 12
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD
MDOC-SOFT50395
7. Precaution at using this function
7.1 Recommended Nozzle Type
It is recommended to use this function for the following nozzle type.
Table 7.1 Recommended Nozzle Type
Series Model Recommended nozzle type
V30 YS12 / YS12P / YS12F
/YG12 / YG12F
301 / 311
YS88 221
YS100 301 / 311
YS24 301 / 311
YS24X 301 / 311
YC8 61
V40 YSM20 301 / 311
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD
MDOC-SOFT50395
7.2 Nozzle Specifications at update
This function is available in the following software version or later.
V30 Series : V3.45STD_R1.000
V40 Series : V4.49STD_R1.000
When the software with this function supported is initially installed, [Parts Fall Vacuum
Level] in the machine setting is set with”5” only for the recommended nozzle type, and set
with “0” for the others.On YS88, however, it is set with “0” for all nozzle types, so that you
need to change it to “5” by hand.
Updating [Nozzle Spec Info.] as well as updating the software
When the software is updated to a version with this function supported from
unsupported version, check the [Nozzle Spec Info.] check box on the [Spec Update]
dialog, and only the recommended nozzle type is set with “5”, and the others are set
with “0”. However, updating [Nozzle Spec Info.] as well as updating the software
makes the other nozzle specifications change. If you don’t want to change the other
nozzle specifications, refer to “Not updating as well as updating the software”.
Fig 7.1 Nozzle Spec Update
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD
MDOC-SOFT50395
Not updating [Nozzle Spec Info.] as well as updating the software
If you don’t want to change the nozzle specifications other than [Parts Fall Vacuum Level],
do not check the [Nozzle Spec Info.] check box at updating the software. [Parts Fall
Vacuum Level] of all nozzle types are set with 0”. Please change the setting of only the
recommended nozzle to “5” as described in “Table 5.1 Machine Setting”.