00197962-01_2nd_HMI_and_Tower_Light_en.pdf - 第24页

Installing a Second Human Machine Interface Installing the HMI Tower Kit 2.4.3 Step 3: Securing the 17-Inch monitor 24 Assembly Instructions SIPLACE E ► Secure the HMI frame on the insi de of the base machine using tw o …

100%1 / 48
Installing a Second Human Machine Interface
2.4.2 Step 2: Mounting the HMI Frame Kit to the Base Machine Installing the HMI Tower Kit
Assembly Instructions SIPLACE E 23
Route the cable bundle at bottom of the HMI frame into the base machine cable inlet hole.
Secure the two ISO 4762 M6x12 base machine screws on the outside of the base machine.
Align and mount the HMI frame onto the two screws.
Installing a Second Human Machine Interface
Installing the HMI Tower Kit 2.4.3 Step 3: Securing the 17-Inch monitor
24 Assembly Instructions SIPLACE E
Secure the HMI frame on the inside of the base machine using two ISO 4762 M6x20 screws (1).
Replace the two ISO 10642 M3x8 cap screws and the bottom cover that you removed earlier.
2.4.3
2.4.3 Step 3: Securing the 17-Inch monitor
Step 3: Securing the 17-Inch monitor
Secure the 17-inch monitor with USB AS-1707A to the HMI frame kit with four ISO 4762 M4x8 cap
screws (1).
Installing a Second Human Machine Interface
2.4.4 Step 4: Connecting the Cables to the Monitor Installing the HMI Tower Kit
Assembly Instructions SIPLACE E 25
2.4.4
2.4.4 Step 4: Connecting the Cables to the Monitor
Step 4: Connecting the Cables to the Monitor
Connect the HMI frame top cables to the monitor.