00197962-01_2nd_HMI_and_Tower_Light_en.pdf - 第25页

Installing a Second Human Machine Interface 2.4.4 Step 4: Connecting the Cables to the Monitor Installing th e HMI Tower Kit Assembly Instructions SIPLACE E 25 2.4.4 2 . 4 . 4 S t e p 4 : C o n n e c t in g t h e C a b l…

100%1 / 48
Installing a Second Human Machine Interface
Installing the HMI Tower Kit 2.4.3 Step 3: Securing the 17-Inch monitor
24 Assembly Instructions SIPLACE E
Secure the HMI frame on the inside of the base machine using two ISO 4762 M6x20 screws (1).
Replace the two ISO 10642 M3x8 cap screws and the bottom cover that you removed earlier.
2.4.3
2.4.3 Step 3: Securing the 17-Inch monitor
Step 3: Securing the 17-Inch monitor
Secure the 17-inch monitor with USB AS-1707A to the HMI frame kit with four ISO 4762 M4x8 cap
screws (1).
Installing a Second Human Machine Interface
2.4.4 Step 4: Connecting the Cables to the Monitor Installing the HMI Tower Kit
Assembly Instructions SIPLACE E 25
2.4.4
2.4.4 Step 4: Connecting the Cables to the Monitor
Step 4: Connecting the Cables to the Monitor
Connect the HMI frame top cables to the monitor.
Installing a Second Human Machine Interface
Installing the HMI Tower Kit 2.4.5 Step 5: Connecting the HMI Frame Cables to the Base Machine
26 Assembly Instructions SIPLACE E
2.4.5
2.4.5 Step 5: Connecting the HMI Frame Cables to the Base Machine
Step 5: Connecting the HMI Frame Cables to the Base Machine
Connect the HMI frame tower light cable [03115364-xx] to –X55 of the HMI LOC cable.
Location 1: Cable, HMI LOC1 (two safety loops) [03110630-xx]
Location 2: Cable, HMI LOC2 (two safety loops) [03110636-xx]
Connect the HMI frame pushbuttons emergency switch cable [03110726-xx] (1) to –X53 of the HMI
LOC cable:
Location 1: Cable, HMI LOC1 (two safety loops) [03110630-xx]
Location 2: Cable, HMI LOC2 (two safety loops) [03110636-xx]