TS577R-UserGuide.pdf - 第13页
13 2. To uch the “Run Method” icon 3. En ter the delay time (ex. 5000 ms) 4. To uch the “Countinous Run” icon 5. To uch the Check Mark icon to save and exit The screen will look similar ly to the screen below: Note: If t…

12
4. Touch the Check Mark icon to save and exit
Note: if suck back is needed, touch the “Reverse” icon to
setup motor reverse time
5. Press the foot switch to activate the “Timed” dispense cycle.
Alternately, touch the Run icon to activate the “Timed” dispense cycle.
Note: The unit has an “Interrupt” mode feature. In this mode, the
“Timed” dispense cycle can be disrupted if the foot switch is released and
resumed when the foot switch is depressed again.
6. Touch the “Interrupt” icon to activate “Interrupt” mode.
The icon will turn to green color.
5.2.7 Teach Mode Setting
In the teach mode, the dispense time will be accumulated as long as the
foot switch is depressed. This is helpful in determining the required
dispense time when dispense output is known.
1. Touch the “Teach” icon to enter the teach mode
2. Touch the “Time Reset” icon to set timer to zero
3. Press and hold down the foot switch, the dispense time will be
accumulated
4. Release the foot switch when the desired amount of fluid has dispensed
5. Touch the “Timed” icon to transfer the dispense time to “Timed” mode
6. The unit is now set to repeat this “Timed” cycle
5.2.8 To run in Continous Mode
The controller can be setup to repeat the run continuously.
1. Touch the Setup icon to enter the setup screen

13
2. Touch the “Run Method” icon
3. Enter the delay time (ex. 5000 ms)
4. Touch the “Countinous Run” icon
5. Touch the Check Mark icon to save and exit
The screen will look similarly to the screen below:
Note: If the controller is set to activate memory cell 1 and the delay time is
set at 5000 ms, the controller will activate memory 1 contiuously with 5000
ms delay between each activation.

14
5.3 Setup for Auger Valve with Encoder Motor
Procedure to control encoder motor valve is very similar to non-encoder valve.
The dispense cycle of encoder motor valve is controlled mainly through
encoder counts.
1. Touch the Setup icon to enter the setup screen
2. Touch the Controller type icon to switch to Encoder controller
“E-Pump Controller”
3. Touch the X icon to save and exit
4. Touch the Dispense icon to enter the setup screen
5. Touch the Up or Down arrows to set the dispense encoder count
Note: if suck back is needed, touch the “Reverse” icon to setup
motor reverse encoder count
6. Touch the Check Mark icon to save and exit
7. Select desired dispense mode to continue (Timed, Interrupt, Teach or Purge)